RSTP Port Configuration

Configure path cost and priority of each port.

1. Select the port in Port column.

1. Path Cost: The cost of the path to the other bridge from this transmitting

bridge at the specified port. Enter a number 1 through 200000000.

2. Priority: Network priority. Enter a number between 0 and 240. The value

must be a multiple of 16.

3. P2P: Some of the rapid state transactions that are possible within RSTP

are dependent upon whether the port concerned can only be connected

to exactly one other bridge (i.e. it is served by a point-to-point LAN

segment), or can be connected to two or more bridges (i.e. it is served

by a shared medium LAN segment). This function allows the P2P status

of the link to be manipulated administratively. True is P2P enabled.

False is P2P disabled.

4. Edge: The port directly connected to the end stations cannot create a

bridging loop in the network. To configure the port as an edge port, set

the port to ‘True’ status.

5. Non STP: Set True to disable STP mathematic calculation. Set False to

including the STP mathematic calculation.

6. Click

Apply

.

RSTP Per Port Configuration interface