Rs-232 control port, A and +12v control @ 50ma. see – B&K Series 2 User Manual

Page 38

Advertising
background image

RS-232 Control Port

The RS-232 port refers to the main RJ-45 connection
located on the preamplifier's back panel. The RJ-45
contains connections for transmission and reception of
RS-232 data. See pin-out at right. The RJ-45 also
supports power supply and IR input for CK1.2 Keypad
interface.

Port - When disabling the RS-232 port, RS-232 strings
will be neither transmitted nor received through the
main RJ-45 jack. By default the RS-232 port is enabled.

Baud rate - The default baud rate is 9600. B & K does not recommend using any baud rate other than 9600.
When a Baud rate other than 9600 is used, Keypad status will not function.

Echo - Enabled or Disabled. This setting is for those with external control systems communicating to B & K
products via RS-232. Echo will repeat RS-232 transmissions received through the main RJ-45 receive port.

Feedback (RS-232 Continuous Reply):

None (Default) = Neither BKC-DIP Update or Reply is generated.
Update = A change affecting a logical zone from the Front Panel or

B & K IR generates an update message representing the specific front panel
button or B & K IR command. The preamplifier must then be polled to deter-
mine the current status.

Reply = When set to “REPLY”, the preamplifier will automatically

generate BKC-DIP reply messages to allow unsolicited continuous feedback
to an external RS-232 controller. A change affecting Zone A or Zone B from
the Front Panel or B & K IR generates a reply message representing the new
status of the parameter that was changed.

Typical format example of a BKC-DIP Reply :

An example BKC-DIP Reply message the Reference 51 Series2 will automatically generate when a master
volume change is executed in Logical Zone 1 is (0,R,P1=FF,1=60;). Reply message Logical Zone 1 current
Preset parameter Volume value is set to 60 hex or 0dB (assumes 0dB is the current setting).

“0” is the transmit ID
“R” is the BKC-DIP Reply message.
“P1=FF” is the BKC-DIP command for the current preset in logical Zone 1 (P1: main theater zone ID).
“1=60” is the current preset parameter (1: Volume), is set to the Hex value of 60 (volume at 0dB ).

For a complete list of B & K RS-232 parameter Protocol, see the Series_IIIS2_10000.pdf or greater located in
the documentation of BKcSuite or online at B & K ’s website.

All (Both) = Outputs both a BKC-DIP Update and Reply messages.

Receive ID / Transmit ID - This is the identifier in B & K RS-232 protocol that allows B & K to “listen” (receive
ID) or “talk” (transmit ID) to other B & K products. Change this identifier if you are using an external automa-
tion system to control more than one B & K products in series. The transmit and receive IDs are denoted by
the first number in an RS-232 message i.e. (0,S,I,1=45;).

Note - If you change the Receive or Transmit ID, it does not affect setup with BKcSuite.

36

R

RS

S-

-2

23

32

2

P

PO

OR

RT

T

S

SE

ET

TU

UP

P

1

1

P

Po

or

rt

t

E

En

na

ab

bl

le

ed

d

2

2

B

Ba

au

ud

d

r

ra

at

te

e

9

96

60

00

0

3

3

E

Ec

ch

ho

o

D

Di

is

sa

ab

bl

le

ed

d

4

4

F

Fe

ee

ed

db

ba

ac

ck

k

N

No

on

ne

e

5

5

R

Re

ec

ce

ei

iv

ve

e

I

ID

D

0

0

6

6

T

Tr

ra

an

ns

sm

mi

it

t

I

ID

D

0

0

↑↑↓↓ nneexxtt iitteemm EENNTT sseelleecctt

M

ME

EN

NU

U

a

ad

dv

va

an

nc

ce

ed

d

s

se

et

tu

up

p

IR

12v

12v

CTR

TX

12v

TX

RCV

12VDC Power Supply

IR

IR Input

CTR

12VDC Control Output

RS-232 Host Transmit

Signal/Common Ground

RCV

RS-232 Host Receive

Advertising