SERVICING INSTRUCTIONS (continued)

REPLACE SOLENOID


Symptom: Automatic brewer will not flow water; or,
automatic brewer drips continuously from brew head.


Unplug power cord or turn circuit breaker OFF. Turn OFF and
disconnect water supply from brewer inlet fitting. Remove rear
access panel.


Unscrew water inlet piping from solenoid.


Remove solenoid from brewer.


Note position of brew water and bypass water tubes on solenoid
Remove tubes from solenoid.


Disconnect wiring from solenoid.


Reassemble in reverse order.

CLEAN SOLENOID SCREEN


Symptom: Automatic brewer will not flow water.


Unplug power cord or turn circuit breaker OFF. Turn OFF and
disconnect water supply from brewer inlet fitting.


Unscrew water inlet fitting from solenoid.


Using needle-nose pliers, withdraw strainer screen from solenoid.
Clean screen under faucet. A stiff bristle brush may be used if
necessary.


Reinsert screen in solenoid. Be careful to maintain correct
orientation. (The OPEN END of the screen goes in FIRST.)


Reassemble in reverse order.

REPLACE TIMER ASSEMBLY


Unplug power cord or turn circuit breaker OFF.


Remove top wrap. Remove knob and three screws holding timer
to bracket. Disconnect wiring to timer.


Reassemble in reverse order.
Adjust timer as described on page 13

14

Fig. 12 Clean Strainer Screen