Fig. 4 Brewer Operation Diagram

A. START-UP


For initial start-up, or if the brewer has not been used for an

extended period of time:

♦ Be sure spray disk and brew gasket are properly installed in the

brew head.

♦ Be sure the water supply is properly connected and the water

supply valve is turned ON.

♦ Be sure the WATER TANK IS FILLED.


IMPORTANT: Fill the water tank before energizing this unit:
1. Insert the brew chamber (empty) and place an empty dispenser in

place under the brew chamber.

2. Be sure the TANK HEATER SWITCH is "

OFF

". Plug the unit into an

appropriate

receptacle.

3. Press The BREW switch. Water will start filling the tank. Run

several consecutive brew cycles until water flows from the brew

chamber.
5. When water stops dripping from the brew chamber, empty the

dispenser, then press TANK HEAT switch "

ON

". The heating

element will begin heating water in the tank. When the water has
reached the proper brewing temperature, the “READY TO BREW”
light will glow.

IMPORTANT:
Tank must be full of water
before pressing TANK
HEATER SWITCH "

ON

".

Heating elements will be
damaged if allowed to
operate without being
fully submerged in water.
Damage caused by
operating the brewer
without water in the tank
is NOT COVERED BY
WARRANTY
.

6