B&B Electronics 8 PORT SMART SWITCH CE 232D4SS8 User Manual

Page 6

Advertising
background image

4

Documentation Number 232D4SS84502 Manual

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

Port Configuration

The 232D4SS8 has a Master port and eight selectable ports

labeled "A" through "H". Refer to “Rear View”. The Master port
should be connected to the RS-232 device that will be selecting the
ports. Ports "A - H” connect to the RS-232 or RS-422/485 devices
that will communicate with the Master port device.

Master Port

The Master port can be configured by the user as a DCE or a

DTE port. In order to determine the proper Master port
configuration of the 232D4SS8 it is necessary to have a basic
understanding of the terms DCE and DTE. RS-232 was designed,
using DB-25 connectors, for connecting a DTE (Data Terminal
Equipment) device to a DCE (Data Communication Equipment)
device. Each device will have inputs on pins that correspond to
outputs on the same pins of the other device. For example, a DTE
device transmits data out on pin 2 and a DCE device receives data
in on pin 2. IBM PC's are DTE devices, modems are DCE devices.
The Master port is shipped configured as a DCE port.

Table 1. Communication & Configuration Switch

DIP Switch 1

1

2

3

4

5

6

7

8

Setting

0

0

0

0

X

X

X

X

300 Baud

1

0

0

0

X

X

X

X

600 Baud

0

1

0

0

X

X

X

X

1200 Baud

1

1

0

0

X

X

X

X

2400 Baud

0

0

1

0

X

X

X

X

4800 Baud

1

0

1

0

X

X

X

X

9600 Baud *

0

1

1

0

X

X

X

X

19.2K Baud

1

1

1

0

X

X

X

X

38.4K Baud

X

X

X

X

0

X

X

X

8 Data Bits *

X

X

X

X

1

X

X

X

7 Data Bits

X

X

X

X

X

0

X

X

Smart Switch Mode *

X

X

X

X

X

1

X

X

Smart Switch and
Port Combiner Mode

X

X

X

X

X

X

0

X

3 Char. Command *

X

X

X

X

X

X

1

X

4 Char. Command

X

X

X

X

X

X

X

0

Port Select Test Off *

X

X

X

X

X

X

X

1

Port Select Test On

0 = OFF

1 = ON

X = DON'T CARE

* = FACTORY DEFAULT

Advertising