Operation, Technical specifications – Belkin AP20500EA3M User Manual

Page 14

Advertising
background image

13

B

elkin

P

ow

er
C

ons
ole

Operation

Central LED Control Panel

The Belkin Power Console is equipped with an LED display
that monitors the vital functions of the Power Console.
A. Switched ON Indicator Light – indicates that the

“Switched” sockets are receiving power.

B. Wiring OK Indicator Light – indicates whether the AC

socket to which the Power Console is connected is wired
properly, or cross-wired. If the “Wiring OK” indicator
does not light, then the live and neutral wires are reversed. See page
15 of the “Troubleshooting” section for more information.

C. Earth OK Indicator Light – indicates if the Power Console is

connected to a properly earthed AC socket. If the “Earth OK”
indicator does not light, this indicates that the AC wall socket is not
properly earthed. See page 14 of the “Troubleshooting” section for
more information.

D. PureFilter Indicator – indicates that the multiphase PureFilter

Circuitry is functioning properly.

Technical Specifications

Specification

PF30

Electrical Rating

240V~10A/2400W

Product Weight (kg.)

4.0kg.

Product Dimensions (mm)

435 x 205 x 92mm (LxWxH)

Number of Sockets

5 Sockets

Cable Length

3M - SD500

Joule Rating

3850J

Maximum Spike Current

132,000A

Response Time

<1 nanosecond

Coaxial Protection

3-in; 3-out

Telephone Protection

1-in; 2-out

Ethernet Protection

1-in; 1-out

Overload Protection

Yes

Advertising