Performance data (cont) – Bryant 601A User Manual

Page 15

Advertising
background image

—15—

PERFORMANCE DATA (cont)

COOLING EXTENDED PERFORMANCE TABLE

HEATING EXTENDED PERFORMANCE TABLE

-10–20

HEATING EXTENDED PERFORMANCE TABLE 30–60

*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 18.

601A042 (3.5 TONS)

Temp (F)

Air Ent

Outdoor Coil

(Edb)

Indoor Entering Air—CFM/BF

1225/0.06

1400/0.075

1575/0.110

Indoor Entering Air—Ewb (F)

72

67

63*

62

72

67

63*

62

72

67

63*

62

85

TC

46.5

43.0

39.9

39.2

47.1

43.8

40.7

40.4

47.4

44.4

41.4

41.4

SHC

24.1

30.7

29.4

36.5

25.3

32.8

31.6

39.0

26.4

34.9

33.6

41.4

kW

4.11

4.04

3.98

3.96

4.12

4.05

3.99

3.99

4.13

4.06

4.00

4.01

95

TC

45.0

41.3

37.9

37.3

45.7

42.0

38.8

38.5

46.1

42.6

39.6

39.8

SHC

23.6

30.0

28.5

35.5

24.8

32.1

30.6

37.9

26.1

34.2

32.6

39.8

kW

4.48

4.39

4.29

4.27

4.49

4.41

4.32

4.32

4.49

4.42

4.36

4.37

105

TC

43.1

39.1

35.7

34.9

43.7

39.9

36.2

35.7

44.2

40.6

38.2

38.0

SHC

22.8

28.9

27.9

34.9

24.2

31.2

30.4

35.7

25.4

33.3

32.2

38.0

kW

4.84

4.75

4.59

4.59

4.86

4.78

4.63

4.59

4.87

4.80

4.84

4.71

115

TC

41.1

34.7

33.3

33.3

41.8

37.6

34.7

34.8

42.2

38.3

36.1

36.2

SHC

22.1

24.3

27.4

33.3

23.5

30.4

29.4

34.8

24.9

32.3

31.5

36.2

kW

5.23

4.88

4.90

4.92

5.25

5.11

5.01

4.98

5.27

5.15

5.13

5.05

601A042 (3.5 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

-10

0

10

17

20

60

1225

TC

14.49

13.27

18.16

16.65

21.92

20.04

24.94

22.77

26.44

23.90

kW

2.63

2.73

2.83

2.91

2.95

1400

TC

14.77

13.55

18.54

17.03

22.30

20.42

25.31

23.05

26.82

24.18

kW

2.68

2.78

2.88

2.94

2.97

1575

TC

15.06

13.83

18.82

17.31

22.58

20.70

25.59

23.34

27.10

24.46

kW

2.75

2.83

2.92

2.98

3.01

70

1225

TC

13.46

12.33

17.31

15.90

21.17

19.48

24.18

22.02

25.69

23.15

kW

2.74

2.88

3.01

3.10

3.14

1400

TC

13.74

12.70

17.69

16.18

21.55

19.76

24.56

22.39

26.06

23.52

kW

2.80

2.93

3.06

3.13

3.17

1575

TC

14.11

12.99

17.97

16.56

21.92

20.14

24.94

22.68

26.44

23.81

kW

2.87

2.98

3.11

3.17

3.20

80

1225

TC

12.23

11.29

16.28

14.96

20.32

18.63

23.34

21.27

24.84

22.39

kW

2.83

3.00

3.18

3.28

3.33

1400

TC

12.51

11.57

16.65

15.24

20.70

19.01

23.71

21.64

25.22

22.77

kW

2.90

3.06

3.22

3.32

3.36

1575

TC

12.89

11.86

16.94

15.62

21.08

19.29

24.09

21.92

25.59

23.05

kW

2.96

3.11

3.27

3.36

3.40

601A042 (3.5 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

30

40

47

50

60

60

1225

TC

31.43

27.57

36.89

36.89

40.84

40.84

41.40

41.68

42.91

42.91

kW

3.06

3.18

3.27

3.27

3.20

1400

TC

31.80

27.85

36.98

36.98

41.03

41.03

41.50

40.46

43.94

43.94

kW

3.07

3.19

3.28

3.29

3.23

1575

TC

32.09

28.13

37.07

36.41

41.50

38.67

41.59

39.71

46.01

46.01

kW

3.11

3.20

3.27

3.39

3.34

70

1225

TC

30.77

27.01

36.04

36.04

40.65

40.65

41.21

41.21

44.41

44.41

kW

3.28

3.40

3.55

3.58

3.52

1400

TC

31.15

27.29

36.51

36.51

40.74

40.74

41.31

41.31

45.07

45.07

kW

3.29

3.42

3.54

3.51

3.54

1575

TC

31.43

27.57

36.70

36.70

40.84

40.84

41.40

41.40

46.48

46.48

kW

3.31

3.44

3.54

3.48

3.64

80

1225

TC

29.83

26.16

35.19

35.19

39.71

39.71

41.12

41.12

45.54

45.54

kW

3.49

3.65

3.77

3.81

3.85

1400

TC

30.30

26.53

35.76

35.76

40.18

40.18

41.21

41.21

46.39

46.39

kW

3.51

3.64

3.78

3.81

3.90

1575

TC

30.67

26.91

36.04

36.04

40.27

40.27

41.31

41.31

47.42

47.42

kW

3.54

3.66

3.78

3.82

4.00