Pressure Testing Burner System Gas
Connections


1. Open equipment shutoff valve (see

Figure 33 page 16).

2. Open propane/LP supply tank valve

for propane/LP burner system or main
gas valve located on or near gas meter
for natural gas burner system.

3. Make sure control knob of burner

system is in the OFF position.

4. Check all joints from equipment

shutoff valve to thermostat gas valve
(see Figure 34 for propane/LP or
Figure 35 for natural). Apply
commercial leak test solution to all gas
joints. Bubbles forming show a leak.
Correct al leaks at once.

5. Light burner system (see Operating

Stove with Burner System, pages 21
through 22). Check all other internal
joints for leaks.

Equipment Shutoff Valve

Propane /LP Supply
Tank

Gas Valve Location

Figure 34– Checking Gas Joints for Propane/LP Gas Burner System

CONTROL VALVE LOCATION

EQUIPMENT
SHUTOFF
VALVE

GAS METER

Figure 35– Checking Gas Joints for Natural Gas Burner System