Cleaning & maintenance, Prepare hood location, Operation – Broan APE1 User Manual

Page 2: Ape1 series page 2

Advertising
background image

APE1 SERIES

Page 2

CLEANING & MAINTENANCE

For performance, appearance, and health reasons, clean filter,

fan and grease-laden surfaces. Use

only a clean cloth and mild

detergent solution on stainless and painted surfaces. Clean all-

metal filters in the dishwasher.
The motor is permanently lubricated and never needs oiling. If

the motor bearings make excessive or unusual noise, replace

the motor with the exact service motor. The impeller should also

be replaced.
Use 120 V, 42 W fluorescent lamp GX24Q-4. For night light, use

4 W, C-7 bulbs. (Bulbs included with hood.)
The grease filters, bottom panel, and blower wheel should be

cleaned frequently. Use a warm detergent solution. The grease

filters and blower wheel are dishwasher safe.
Note: Some minerals, when in contact with dishwasher soap

additives, may cause filters to discolor. This discoloration is not

covered by the warranty.

PREPARE HOOD LOCATION

SOFFIT

18" - 24" ABOVE

COOKING SURFACE

CABINET

3¼" X 10" DUCT

(For horizontal discharge)

WALL CAP

ROOF CAP

3¼" X 10"

(For vertical

discharge)

HOUSE WIRING

(Top or Back of hood)

HOOD

HOOD

1

Determine whether hood will discharge vertically or horizon-

tally. For vertical or horizontal discharge, run ductwork be-

tween the hood location and a roof cap or wall cap. For best

results, use a minimum number of transitions and elbows.

OPERATION

Always turn the hood ON before cooking in order to establish an

air flow in the kitchen. After turning off the range, let the hood run

for a few minutes to clear the air.

HEAT SENTRY™
The hood is equipped with a Heat Sentry™ thermostat. This safety

device will turn on or speed up the blower if it senses excess heat

above the cooking surface.

If the blower is not on, or if it is running at low speed, the Heat

Sentry™ will override the normal blower control and run the blower

on the high speed. When the temperature level drops to normal

levels, the blower will return to its original setting.

Operate the hood as follows:

FAN
The 2-position switch (in center) turns blower ON and OFF.
The 5-position switch (at left) controls blower speed.

Blower is OFF (secondary blower OFF).
Blower is ON at highest speed.

As dots get smaller - blower speed decreases.

LIGHT

This 3-position switch (at right) turns lights ON and OFF and

controls their intensity.

Lights are OFF.

Night Light is ON.
Fluorescent Light is ON.

LIGHT

FAN

FAN

ON

OFF

CABINET

BOTTOM

CABINET FRONT

HORIZONTAL DUCT

ACCESS HOLE

6¼"

6¼"

3/4

"

HOOD

MOUNTING

SCREWS (4)

ELECTRICAL

ACCESS HOLE

(in wall)

3

7/8

"

CENTER

LINE

WOOD SHIMS

(recessed-bottom

cabinets only)

7

1/2

"

1/8

"

16

15

/

16

"

(36" hood)

16

15

/

16

"

(36" hood)

13

15

/

16

"

(30" hood)

13

15

/

16

"

(30" hood)

9"

CENTER

LINE

HOOD MOUNTING SCREWS (4)

ELECTRICAL

ACCESS HOLE

(in cabinet bottom)

WOOD SHIMS

(recessed-bottom

cabinets only)

CABINET FRONT

CABINET

BOTTOM

16

15

/

16

"

(36" hood)

16

15

/

16

"

(36" hood)

13

15

/

16

"

(30" hood)

13

15

/

16

"

(30" hood)

1

1/2

"

7

1/2

"

VERTICAL DUCT

ACCESS HOLE

6¼"

6¼"

10

5/8

"

6

7/8

"

9

7/8

"

3¼” X 10”

VERTICAL DUCTING

2

Use the proper diagram below, for placement of ductwork

and electrical cutout in cabinet or wall. For a non-ducted

installation, DO NOT cut a duct access hole.

3¼” X 10”

VERTICAL DUCTING