PREPARE THE HOOD

4

Blower is shipped in Vertical Discharge Position.

To change blower to

Horizontal Discharge Position:

Remove

Knurled Nuts from Blower Mounting Rods.

Disengage mounting rods from blower and rotate blower

to horizontal discharge position. Re-engage mounting

rods and tighten blower in place with knurled nuts.

3

Remove the

Aluminum Filters, Bottom Cover, and

Wiring Cover from the hood.

ALUMINUM

FILTERS

BOTTOM

COVER

WIRING

COVER

VERTICAL DISCHARGE POSITION

HORIZONTAL DISCHARGE POSITION

BLOWER

MOUNTING

ROD (2)

KNURLED NUT (2)

BLOWER

MOUNTING

ROD (2)

KNURLED NUT (2)

BLOWER

BLOWER

5

Remove

Vertical Duct Knockout or Horizontal Duct

Knockout and attach Damper / Duct Connector with

two (2) screws (supplied).

VERTICAL DUCT

KNOCKOUT

HORIZONTAL DUCT

KNOCKOUT

DAMPER /

DUCT

CONNECTOR

INSTALL THE HOOD

WARNING

To reduce the risk of electrical shock, switch power off

at service panel. Lock or tag service panel to prevent

power from being switched on accidentally.

6

Run

House Power Cable between service panel and

hood location. Attach power cable to hood using appropri-

ate connector.

7

Hold the hood in position under the cabinet. Make sure

the damper / duct connector enters the

Ductwork and

that the damper opens and closes freely.

8

Tighten the four (4)

Mounting Screws completely to se-

cure the hood to the cabinet.

HOUSE

POWER

CABLE

MOUNTING

SCREWS (4)

DUCTWORK