Wire the burner, R7184b – Beckett CF1400 User Manual

Page 14

Advertising
background image

14

Form 6104 BCF23-R05

Wire the burner

— R7184B

Install the burner and all wiring in accordance with the National
Electrical Code and all applicable local codes or requirements.

Wire the burner in compliance with all instructions provided by
the appliance manufacturer. Verify operation of all controls in
accordance with the appliance manufacturer’s guidelines.

See Figure 11 for a typical wiring diagram, with R7184 oil
primary, for reference purposes only.

Figure 11. - Typical wiring (R7184B)

Legend

FD Fused Disconnect, by others

TR Ignition transformer

LM Limit controls, by others

M1 Burner motor

OP Operating controls, by others

S1 Oil valve

PR Oil primary control, R7184 typ.

T-T 24-volt thermostat/limit terminals

CC Flame sensor, cad cell typical

F-F Cad cell fl ame sensor terminals

Disconnect electrical power before installing or
servicing the burner.
Provide ground wiring to the burner, metal control
enclosures and accessories. (This may also be
required to aid proper control system operation)
Perform all wiring in compliance with the National
Electric Code ANSI/NFPA 70 (Canada CSA
C22.1).

y

y

y

Electrical shock can cause severe personal in-

jury or death.

Electrical Shock Hazard

Advertising
This manual is related to the following products: