Bunn FMD-1 User Manual

Page 9

Advertising
background image

9

Water is not hot (Cont.)

Spitting or excessive steaming

Dripping from dispense tip

Water flows into tank continuously

4. Tank heater switch

1. Lime build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water conditions.
Excessive mineral build-up on stain-
less steel surfaces can initiate corro-
sive reactions resulting in serious
leaks.

2. Control thermostat

1. Lime build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water conditions.
Excessive mineral build-up on stain-
less steel surfaces can initiate corro-
sive reactions resulting in serious
leaks.

2. Dispense solenoid valve

1. Level control board and probe

2. Solenoid valve (Inlet)

3. Overflow Protection Switch

Refer to

Service

- Tank Heater Switch

for testing procedures. See page 29

Inspect tank assembly for excessive
lime deposits. Delime as required.

Refer to

Service

- Control Thermo-

stat for testing procedures. See
page 15

Inspect the tank assembly for exces-
sive lime deposits. Delime as re-
quired.

Remove the dispense solenoid valve
and clear any obstructions. Rebuild
or replace the valve if necessary. See
page 26

Refer to

Service -

Level Control Board

and Probe for testing procedures.
See page 22

Refer to

Service

- Solenoid Valve

(Inlet) for testing procedures. See
page 27

Refer to

Service

- Overflow Protec-

tion Switch for testing procedures.
See page 24

TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY

28364 041598