Bunn TU3Q-EZ User Manual

Page 19

Advertising
background image

Page 19

SERVICE (cont.)

TANK HEATER

FIG. 10 TANK HEATER

Location:

The tank heater is located inside the tank and

secured to the tank lid.

Test Procedures:
1. Disconnect the brewer from the power supply.
2. With a voltmeter, check the voltage across the

black and white wires. Connect the brewer to the
power source. The indication must be 120 volts
ac for two wire 120 volt models .

3. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4
If voltage is not present as described, refer to the

Wir-

ing Diagrams

and check wiring harness.

4. Disconnect the black wire and the white wire from

the tank heater terminals.

5. Check for continuity across the tank heater termi-

nals.

If continuity is present as described, reconnect the
wires, the tank heater is operating properly.
If continuity is not present as described, replace the
tank heater.
NOTE- If the tank heater remains unable to heat, re-

move and inspect heater for cracks in the sheath.

Removal and Replacement:
1. Disconnect the black wire and the white wire from

the tank heater terminals.

2. Remove sprayhead and the hex nut securing the

sprayhead tube to the hood. Set aside for reas-
sembly.

3. Disconnect vent tube.
4. Remove the six #10 thread cutting screws secur-

ing the tank lid to the tank. Remove the green wire.

5. Remove the tank lid with limit thermostat, spray

head tube, tank heater and vent tube.

6. Remove the two hex nuts securing the tank heater

to the tank lid. Remove tank heater with gaskets
and discard.

7. Install new tank heater with gaskets on the tank

lid and secure with two hex nuts.

8. Install tank lid with limit thermostat, sprayhead

tube, tank heater and vent tube and the green wire
using six #10 thread cutting screws.

9. Secure sprayhead tube to hood using a hex nut.
10. Install sprayhead.
11. Connect vent tube to fitting.
12. Reconnect the wires to the limit thermostat, tank

heater. See

Limit Thermostat

section in this manual

when reconnecting wires.

13. Refer to Fig.11 when reconnecting the tank heater

wires.

FIG. 11 TANK HEATER TERMINALS

P1284

P1798.40

WHI to Power Cord

BLK to Limit
Thermostat

29460 061599