Troubleshooting – InnoMax Adjustable Bed Base User Manual

Page 17

Advertising
background image

PowerBASE™ Owners Manual 99300787-i

17

TrOuBlesHOOTinG

In the event the PowerBASE

adjustable bed fails to operate, investigate the symptoms

and possible solutions provided in the chart below:

syMpTOM

sOluTiOn

• Verify power cord is plugged into a working,

grounded electrical outlet.

a grounded,

electrical surge protection device is recommended.

Test outlet by plugging in another working appliance.

• Program the hand control (see Hand control

Programming section of this manual for
programming procedures). If equipped with power
down box, make certain power down box is easily
accessible. Relocate power down box if required.

• Unplug power cord, wait 30 seconds and plug in to

reset electronic components.

• Electrical circuit breaker may be tripped. check

electrical service breaker box to verify.

• Defective surge protection device or electrical outlet.

Test outlet by plugging in another working appliance.

• Replace batteries in the hand control.

• Bed mechanism may be obstructed. Elevate bed and

check for obstruction. Remove obstruction.

• Head section may be too close to the wall.
• Headboard may be too close the edge of the

mattress. Verify a 1.5” (38.1mm) to 2” (50.8mm)
distance between headboard brackets and mattress.
Adjust if required.

• Verify headboard brackets were removed during

installation. Remove headboard brackets if still
attached to the underneath side of bed.

• If bed is located on hard surface flooring, place

carpet pieces or rubber caster cups under each leg
or caster of the bed. (See accessory sheet, included
with this product, for rubber caster cup order
information.)

• Elevate the head or foot section a short distance

(with the hand control) to realign the lift/lower
mechanisms with the bed support platform.

• Verify that bed is not positioned against a wall,

nightstand, or other object that may cause vibration
or noise.

• If adjustable bed is installed over a bed frame, verify

massage motors are not causing bed frame (or bed
frame components) to vibrate.

• Verify that headboard attachment hardware is

tightened firmly (if used).

Hand control illuminates and appears to be
operable, but will not activate bed.

No features of the adjustable bed will
activate.

Hand control will not illuminate.

Head or foot section will elevate, but will not
return to the horizontal (flat) position.

Excessive massage motor noise.