Class1 Valve - 119138 User Manual

Page 12

Advertising
background image

12

Class 1 Valve Manual

p/n: 119138

IMPORTANT

• Electric actuators – If an electric actuator is used, route the wire harness away from potentially hot

and/or moving parts. Secure the harness every 10” – 12” (254mm – 309mm) to prevent excessive
movement.

• Testing – After installation, verify that the valve cycles properly from fully OPENED to fully

CLOSED without excessive effort. If equipped with a hand wheel or electric control, verify that
the indicator lights sequence properly, indicating valve OPEN, CLOSE, or in between. Pressure
test valve connections before placing apparatus into service.

5.3 Direct and Remote Handle Installation

1. Remove the hex bolt and washer from the valve stem.
2. Slide the handle over the valve stem, so that it is seated on top of the stop plate.
3. As needed, adjust the handle and stop plate orientation so that the valve is open or closed with the

correct handle position.

4. Apply Loctite #242 or equivalent to the hex bolt and reinstall the bolt and washer to secure the

handle. Torque the bolt to 40 ft-lbs. [As the screw is tightened, ensure that the valve retaining bracket
is aligned so that it slides into the grooves on the valve body.]

5. Open and close the valve several times to check for smooth operation.

Hex bolt & washer

Handle

Stop plate

Retaining bracket seated in

groove (both sides) – Step 4

5. installation

!

!

Advertising