Wash Down Pump Installation

5

Questions?
Call For Technical Support
(208) 687-4400 or
Fax (208) 687-9700
www.heatercraft.com

IMPORTANT NOTE: We recommend that the wash down pump is not mounted into the bilge, or any
location or in such a manner that it would be easily submerged. The warranty for the pump may be void
if, upon disassembly, Heater Craft determines that the pump has been submerged in water for any length
of time.

Mounting the Wash Down Pump

1. Determine the location for mounting the wash down pump. To insure proper draining for cold weather
use, the wash down pump must be mounted above the static water line of the hull. Make sure the rubber
feet are attached to the pump base before mounting pump. If pump will be mounted on fiberglass we
recommend pre drilling screw holes to reduce chipping. Use the four stainless steel screws provided and
tighten as needed.

2. Install the wing-nut fittings by hand then mount the pump in place.

Wiring the Wash Down Pump

The pump wires should be routed with the factory wiring harness whenever possible. The wires should be
routed away from moving parts, high heat sources and sharp edges or objects.

700-S The wash down pump and switch should
be protected with a 10 amp in-line fuse.
• Red positive lead– Wire to an on/off switch
with a 12V DC power source.
• Black negative lead– Wire to ground source.

• 3–Red power wire from wash down pump.
• 2–Wire to a 12V DC power source.
• 7–Wire to a ground source.
• Black negative lead (from wash down
pump)–
Wire to a ground source.

Wash Down Plate

Switch

Switch detail

7

2
3

Advertising