1.

Straighten the mounting bracket tabs and remove
thermocouple from safety control valve.

2.

Remove the jam nut securing the safety control valve
to its mounting bracket.

3.

Pull the safety control with manifold from heater.

4.

Replace or clean components as needed.

FIG. 6

FIG.7

1. Close the fuel supply valve to the heater before

s e r v i c i n g u n l e s s n e c e s s a r y fo r yo u r s e r v i c e
procedure.

2. Disconnect the thermocouple from the safety control

valve when servicing either the pilot saftey control
valve or the burner orifice manifold.

3. Remove the heater’s barrel for access to burner

related components.

4

Disconnect the gas hose if needed for the service
procedure.

5. For reassembly, reverse the respective service

procedure. Ensure gas connections are tightened
securely.

6. After servicing, start the heater to ensure proper

operation and check for gas leaks.

7. Clean the heater’s orifice manifold with compressed

air or a soft, dry rag. Do not use files, drills, etc.,
which may enlarge the holes, causing combustion
problems or burner flame extending outside of the
case barrel. Replace the manifold if its holes cannot
be cleaned properly.

WARNING

Burn Hazard

Heater surfaces are hot for a period of time after the
heater has been shut down.

Allow the heater to cool before performing service,
maintenance, or cleaning.

Failure to follow this warning will result in burns
causing injury.

11

Service Instructions

GENERAL

WARNING

Fire and Explosion Hazard

Do not disassemble or attempt to repair any heater
components or gas train components.

All component parts must be replaced if defects are
found.

Failure to follow this warning will result in fire or
explosions, causing property damage, injury, or death.

SAFETY CONTROL VALVE/VARIABLE RATE

VALVE/BURNER ORIFICE MANIFOLD

JAM NUT

BRACKET

SAFETY
VALVE

ORIFICE
MANIFOLD

VARIABLE RATE
VALVE