Troubleshooting

PROBLEMS

CAUSES

REMEDIES

1. Burner will not light.

* Propane gas container is empty.

* Fill container.

* Fuel supply valves closed.

* Open fuel supply valves.

* Excess flow valve in P.O.L.

* Close propane container valve. Wait 5 minutes

fitting on regulator is closed.

and open container’s valve slowly.

* Safety control button not fully pushed in.

* Push in button completely.

* Burner orifice manifold is plugged.

* Clean or replace manifold.

* Restriction in gas hose.

* Remove hose from heater and blow

out with compressed air or replace if necessary.

* Air in gas line.

* Push in safety control valve’s pilot button (normally 15 -

20 seconds is sufficient) on control of gas valve to purge

air from line (usually necessary at time of installation).

NOTE:

Make sure you are pushing the Piezo igniter
button during this time to prevent gas
accumulation.

* Safety control valve is defective.

* Replace safety control valve.

* Defective Piezo igniter or electrode.

* Refer to the igniter and electrode service instruction

section for problems associated with these parts.

2. Burner lights but will not

* Restriction in gas hose.

* See remedy for same cause in Problem #1.

stay lit when safety control
button is released.

* Insufficient time allowed for

* Hold in control button for 30 seconds to allow proper

thermocouple to heat up..

warm up.

* Loose thermocouple.

* Tighten thermocouple at gas control. Make sure

it is securely pushed into its bracket. Tighten
finger tight and snug the contact nut with an
appropriate wrench.

* Defective thermocouple.

* Replace thermocouple.

* Orifice manifold is plugged.

* See remedy for same in Problem #1.

* Defective safety control valve.

* Replace safety control valve.

* Improper gas pressure.

* Set pressure according to pressure on dataplate.

3. Burner flame lifting

* Fuel pressure set too high.

* Set pressure according to pressure on dataplate.

off burner.

* Blockages in burner manifold orifice or at * Clean suspected area with soft brush, dry cloth,

primary air inlets of burner.

or compressed air.

4. Heater not delivering

* Gas supply valves not fully open.

* Open valves completely.

maximum heat output.

* Variable rate valve not positioned

* Position the valve to maximum

to maximum
Burner manifold orifice plugged.

* Clean burner orifice with compressed air or replace.

* Low fuel supply pressure.

* Consult propane gas supplier. Cylinder or tank needs

replacement or refill. Regulator needs adjustment.
Check for use of proper regulation and fuel gas.

Advertising