Burner orifice motor and fan assembly – L.B. White Sentinel Radiant Tube AT150 Center Mount User Manual

Page 19

Advertising
background image

1. Remove the igniter

2. Remove the clear flexible tube from the pressure

switch. Fig.24.

. 3. Remove the four nuts from the burner mounting studs

and remove burner . See Fig.24.

FIG. 24

4

Securely hold the burner manifold in place while
removing the orifice from the manifold. See Fig. 25.
Inspect the orifice and clean out any dirt. Replace it if
necessary.

FIG. 25

5.

When reinstalling the burner, ensure larger opening
between burner vanes is directed to the access door
of the burner box. See Fig.26

.

FIG. 26

BURNER ORIFICE

MOTOR AND FAN ASSEMBLY

19

NUTS

TUBE

LARGER OPENING

1.

Remove all fan housing mounting nuts. See Fig. 27.

2.

Tilt the motor and fan assembly slightly and pull
upward.

FIG. 27

3.

Remove inlet side of housing. See Fig. 28. Loosen
set screw on fan hub with a TORX 20 driver.

4.

Pull fan wheel from housing. Remove nuts holding
housing to motor mounting studs.

FIG. 28

ORIFICE

MANIFOLD

NUTS

Advertising