Troubleshooting guide – L.B. White I-34 Infraconic Spark Ignition User Manual

Page 19

Advertising
background image

1188

READ THIS ENTIRE SECTION BEFORE

BEGINNING TO TROUBLESHOOT PROBLEMS.

The following troubleshooting flow charts provide systematic

procedures for isolating heater problems. The charts are

intended for use by a QUALIFIED GAS HEATER SERVICE

PERSON. DDOO NNOOTT SSEERRVVIICCEE TTHHEE HHEEAATTEERR UUNNLLEESSSS YYOOUU HHAAVVEE

BBEEEENN PPRROOPPEERRLLYY TTRRAAIINNEEDD..

TEST EQUIPMENT REQUIRED

The following pieces of test equipment will be required to

troubleshoot this system with minimal time and effort.

•• DDiiggiittaall M

Muullttiim

meetteerr - For measuring voltage.

•• PPrreessssuurree GGaauuggee - (Part No. 20736) For checking inlet

pressures to the heaters.

IINNIITTIIAALL PPRREEPPAARRAATTIIOONN

-- Inspect the heater for damage.

-- Clean the heater as necessary.

HHeeaatteerr PPrroobblleem

mss

PPaaggee

1.Heater does not light................................................19

2.Heater lights, but will not stay lit ............................20

3.Heater backflashes gas through air inlet. ..............20

Components should be replaced only after each step has

been completed and replacement is suggested in the flow

chart. Refer to the “Servicing” sections as necessary to

obtain information on disassembly and replacement

procedures of the component once the problem is identified

by the flow chart.

OPERATION SEQUENCE:

••A call for heat occurs from building thermostat.

••Line voltage is sent from building’s temperature control

to heater’s ON/OFF switch.

••Switch sends power to ignition control through high

limit switch.

-- Ignition control module begins ignition trial sequence

-- Ignition control sends high voltage to igniter

electrode

-- Igniter sparks

-- Gas control solenoid opens

••Ignition occurs

-- Igniter continues to spark for 10 seconds until

flame proving occurs

-- Ignition spark is shut off

-- Gas control solenoid stays open

••Ground warms to desired temperature

-- Building thermostat is satisfied

-- Heater shuts down

••Process is repeated on a call for heat

IGNITION FAILURE SEQUENCE:

••Ignition control will make three ignition trials

-- Each trial lasts 10 seconds

-- 15 seconds time span between each trial

••If ignition control does not establish flame sense within

ignition trial:

-- Ignition spark shuts off

-- Gas valve closes

••After three ignition trials, ignition control will wait for 15

minutes before retrying for ignition.

••This process will be repeated continually until the

ignition problem is solved.

••To manually reset the ignition control:

-- Unplug the heater and plug it back in

OR

-- Turn the building temperature control to off and

then back on.

OR

-- Turn ON/OFF switch on heater off. Wait 5

seconds, then turn back on.

Troubleshooting Guide

W

WAARRNNIINNGG

EElleeccttrriiccaall SShhoocckk aanndd BBuurrnn HHaazzaarrdd

Troubleshooting this system may require operating the

heater with the burner on. Use extreme caution when

working on the heater.

Failure to follow this warning may result in electrical

shock or burns causing severe injury.