SECTION 10

8042/10042 Stabil-TRAK Hydraulic Circuit

Free Pivot Mode

(S/N 9909 & After)

CONDITIONS:

Boom below 40°, vehicle stopped, and transmission in forward or reverse.
Solenoids 1 and 2 are energized to permit flow of rear axle stabilizer cylinder oil to hydraulic reservoir and normal frame tilt.
Solenoids 3, 4, 5, and 6 are de-energized.

If vehicle is stopped by service brakes, or park brake switch, or transmission in neutral; the same conditions apply.

BRK

P

SR

TC

TP

V

SB

T

PRESSURE

REDUCING

VALVE

500 - 525 PSI

SOLENOID

3

SOLENOID

4

P

T

CONTROL VALVE

(located on valve plate under cab)

PRESSURE REDUCING VALVE BLOCK

AND STABILIZER VALVE BLOCK

(located on valve plate under cab)

FRAME TILT

VALVE

SECTION

SOLENOID

1

SOLENOID

5

SOLENOID

6

SOLENOID

2

.029

.060

500 - 525

PSI

VARIABLE

DISPLACEMENT

PUMP

45 GPM

FRAME TILT

CYLINDER

STABILIZER CYLINDER

PRESSURE REDUCING

VALVE BLOCK

STABILIZER

VALVE

BLOCK

HYDRAULIC

RESERVOIR

SOL. 3

SOL. 1

SOL. 2

SOL. 4

SOL. 5

SOL. 6

.029

E

R

E

R

PRESSURE REDUCING

VALVE

200 +/- 25 PSI

LS

LS

SH1170

Origin 2/00