Connecting the airdog, Relay control – PureFlow AirDog DF-165 - GM 1992-2000 User Manual

Page 16

Advertising
background image

16

AirDogII

®

1992-2000 Chevy Diesel

Section 6 Electrical Harness

Connecting the AirDog

®

Relay Control

6-2.

Remove the plastic housing covering the fuse box. On some models it may be necessary
to remove the fender/cowl brace to allow access to the fuse box.

6-3.

After accessing the fuse panel, use a test light or voltmeter to find a fuse terminal that is
HOT only when the ignition is in the on/run position. Connect the Red Relay Trigger
wire with the mini fuse tap to that terminal.

Relay

Trigger Lead

Connection







Figure 45 Figure 46

NOTE: The power supply leads can be connected to the battery or the alternator.

Connecting the power supply leads to the alternator instead of the battery will

create a corrosion free connection.

Black (-) Red (+) Replace the Protective Cover






Figure 47

Figure 48

6-4A. Route the Red & Black power supply leads to the alternator

Connect the Black (-) lead to the alternator Chassis Ground connection. Connect the