U-panel, Recommended screw placement table, Fastening schedule spacing along panel nail strip – Mueller U-Panel User Manual

Page 13

Advertising
background image

Details are subject to change without prior notice.

RECOMMENDED SCREW PLACEMENT TABLE

U-PANEL

Zone

FASTENER

SUBSTRATE

90

ON CENTER

SPACING

100

ON CENTER

SPACING

110

ON CENTER

SPACING

120

ON CENTER

SPACING

130

ON CENTER

SPACING

140

ON CENTER

SPACING

Zone 1

#12-11 X 1”

15/32” CDX

19/32” CDX

7/16” OSB

1x4 Wood Purlins

Type 1, 36”

Type 1, 36”

Type 1, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

N/A

Type 1, 24”

Type 1, 30”

Type 1, 30”

N/A

Type 1, 24”

Type 1, 30”

Type 1, 30”

N/A

Type 1, 24”

Type 1, 30”

Type 1, 30”

N/A

N/A

Zone 2

#12-11 X 1”

15/32” CDX

19/32” CDX

7/16” OSB

1x4 Wood Purlins

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

N/A

Type 1, 24”

Type 1, 30”

Type 1, 30”

N/A

Type 1, 24”

Type 2, 24”

Type 2, 24”

N/A

Type 1, 24”

Type 2, 24”

Type 2, 24”

N/A

N/A

Zone 3

#12-11 X 1”

15/32” CDX

19/32” CDX

7/16” OSB

1x4 Wood Purlins

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 2, 24”

Type 2, 24”

N/A

Type 2, 24”

Type 2, 24”

Type 2, 24”

N/A

Type 2, 24”

Type 2, 12”

Type 2, 12”

N/A

Type 2, 24”

Type 2, 12”

Type 2, 12”

N/A

N/A

Zone

FASTENER

SUBSTRATE

90

ON CENTER

SPACING

100

ON CENTER

SPACING

110

ON CENTER

SPACING

120

ON CENTER

SPACING

130

ON CENTER

SPACING

140

ON CENTER

SPACING

Zone 1

#12-11 X 1”

15/32” CDX

19/32” CDX

7/16” OSB

1x4 Wood Purlins

Type 1, 36”

Type 1, 36”

Type 1, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Zone 2

#12-11 X 1”

15/32” CDX

19/32” CDX

7/16” OSB

1x4 Wood Purlins

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Zone 3

#12-11 X 1”

15/32” CDX

19/32” CDX

7/16” OSB

1x4 Wood Purlins

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

Type 1, 30”

Type 1, 30”

Type 2, 30”

Type 1, 24”

WIND SPEED ZONE

FASTENING SCHEDULE SPACING ALONG PANEL NAIL STRIP

With < 30’-0” mean eave height -

3:12 to 6:12 pitch

for 90-140 mph wind speeds based on ASCE 7-93

WIND SPEED ZONE

FASTENING SCHEDULE SPACING ALONG PANEL NAIL STRIP

With < 30’-0” mean eave height -

7:12 to 12:12 pitch

for 90-140 mph wind speeds based on ASCE 7-93