Endwall to roof flashing installation – Mueller U-Panel User Manual

Page 22

Advertising
background image

22

ENDWALL TO ROOF FLASHING INSTALLATION

Details are subject to change without prior notice.

1. Insert the endwall flashing (#0726) behind the existing wall counter-flashing and attach to the wall using

appropriate fasteners. Make sure the receiver hem of the endwall flashing is resting on the top of the roof sheet rib.
If required, cap the ends of the trim by cutting and folding a tab. Remove the hems before making the folds.

2. If there is no counter-flashing, install counter-flashing using appropriate fasteners.

3. Install the outside closure on top of the roof panel. Make sure the closure is in line with the lower flange

of the endwall trim.

4. Install the endwall trim by attaching with lap screws @ 12” O.C. Locate the screws at the high ribs to

prevent dimpling of the endwall trim due to over-tightening.

5. All end laps should be at least 4”. Remove 4” of the hem on the overlapping piece and secure to the

overlapped piece with caulk and stitch screws.

NOTE: Alternate trim profiles are acceptable using the screw pattern shown.

NOTE: To comply with Texas

Windstorm Certification Testing,

#12x11 SDT Type A screws must

be used in place of the #9

Woodgrip screws.