30-3439 AEMnet HARNESS INSTALLATION INSTRUCTIONS

ENGINEER: JT

DATE LAST MODIFIED: 7/9/2013

Page 3 of 4

4. Insert the AEMnet+ terminal (white wire) into the available Pin 13 on the

Wideband Failsafe connector. Push the wire in until the locking mechanism on
the terminal and connector lock into place. Pull lightly on the white wire to
confirm the locking mechanism has latched. Figure 4 below shows the correct
placement of the AEMnet+ terminal.

Figure 4

5. Insert the AEMnet- terminal (green wire) into the available Pin 12 on the

Wideband Failsafe connector. Push the wire in until the locking mechanism on
the terminal and connector lock into place. Pull lightly on the green wire to
confirm the locking mechanism has latched. Figure 5 below shows the correct
placement of the AEMnet- terminal.

Figure 5