C1-20

AGND_1

Sensor Ground

Dedicated analog ground

Analog 0–5V sensor ground

C1-21

Crankshaf t Position
Sensor Hall

Crankshaf t Position

Sensor Hall

10K pullup to 12V. Will work with
ground or f loating switches.

See Setup Wizard page Cam/Crank f or
options.

C1-22

Camshaf t Position
Sensor 1 Hall

Camshaf t Position

Sensor 1 Hall

10K pullup to 12V. Will work with
ground or f loating switches.

See Setup Wizard page Cam/Crank f or
options.

C1-23

Digital_In_2

Camshaf t Position

Sensor 2 Hall

10K pullup to 12V. Will work with
ground or f loating switches.

See Setup Wizard page Cam/Crank f or
options.

C1-24

Digital_In_3

Turbo Speed Hz

10K pullup to 12V. Will work with
ground or f loating switches.

See Setup Wizard page Input Function
Assignment f or calibration constant.
TurboSpeed [RPM] = Turbo [Hz] * Turbo
Speed Calibration.

C1-25

Digital_In_4

Vehicle Speed Sensor

10K pullup to 12V. Will work with
ground or f loating switches.

See Setup Wizard page Input Function
Assignment f or calibration constant.

C1-26

Digital_In_5

Flex Fuel

10K pullup to 12V. Will work with
ground or f loating switches.

See channel FlexDigitalIn [Hz] f or raw
f requency input data.

C1-27

Knock Sensor 1

Knock Sensor 1

Dedicated knock signal
processor

See Setup Wizard page Knock Setup f or
options.

C1-28

Knock Sensor 2

Knock Sensor 2

Dedicated knock signal
processor

See Setup Wizard page Knock Setup f or
options.

C1-29

+12V_Relay _Control

+12V Relay Control

0.7A max ground sink f or
external relay control

Will activ ate at key on and at key of f
according to the conf iguration settings.

C1-30

Power Ground

Ground

Power Ground

Connect directly to battery ground.

C1-31

CANL_Aout

AEMNet CANL

Dedicated High Speed CAN
Transceiv er

Recommend twisted pair (one twist per 2")
with terminating resistor. Contact AEM f or
additional inf ormation.

C1-32

CANH_Aout

AEMNet CANH

Dedicated High Speed CAN
Transceiv er

Recommend twisted pair (one twist per 2")
with terminating resistor. Contact AEM f or
additional inf ormation.

C1-33

LowsideSwitch_1

Boost Control

Lowside switch, 4A max with
internal f ly back diode. Inductiv e
load should NOT hav e f ull time
power.

See Setup Wizard page Boost Control f or
options. Monitor BoostControl [%] channel
f or output state.

C1-34

Lowside Fuel Pump driv e

Fuel Pump

Lowside switch, 4A max, NO
internal f ly back diode.

Switched ground. Will prime f or 2 seconds
at key on and activ ate if RPM > 0.

Advertising