Pin
Hardware Reference
7100-XXXX-62
7101-XXXX-63
Function
Hardware Specification
Notes
C1-20
AGND_1
Sensor Ground
Dedicated analog ground
Analog 0–5V sensor ground
C1-21
Crankshaf t Position
Sensor Hall
Crankshaf t Position
Sensor Hall
10K pullup to 12V. Will work with
ground or f loating switches.
See Setup Wizard page Cam/Crank f or
options.
C1-22
Camshaf t Position
Sensor 1 Hall
Camshaf t Position
Sensor 1 Hall
10K pullup to 12V. Will work with
ground or f loating switches.
See Setup Wizard page Cam/Crank f or
options.
C1-23
Digital_In_2
Camshaf t Position
Sensor 2 Hall
10K pullup to 12V. Will work with
ground or f loating switches.
See Setup Wizard page Cam/Crank f or
options.
C1-24
Digital_In_3
Turbo Speed Hz
10K pullup to 12V. Will work with
ground or f loating switches.
See Setup Wizard page Input Function
Assignment f or calibration constant.
TurboSpeed [RPM] = Turbo [Hz] * Turbo
Speed Calibration.
C1-25
Digital_In_4
Vehicle Speed Sensor
10K pullup to 12V. Will work with
ground or f loating switches.
See Setup Wizard page Input Function
Assignment f or calibration constant.
C1-26
Digital_In_5
Flex Fuel
10K pullup to 12V. Will work with
ground or f loating switches.
See channel FlexDigitalIn [Hz] f or raw
f requency input data.
C1-27
Knock Sensor 1
Knock Sensor 1
Dedicated knock signal
processor
See Setup Wizard page Knock Setup f or
options.
C1-28
Knock Sensor 2
Knock Sensor 2
Dedicated knock signal
processor
See Setup Wizard page Knock Setup f or
options.
C1-29
+12V_Relay _Control
+12V Relay Control
0.7A max ground sink f or
external relay control
Will activ ate at key on and at key of f
according to the conf iguration settings.
C1-30
Power Ground
Ground
Power Ground
Connect directly to battery ground.
C1-31
CANL_Aout
AEMNet CANL
Dedicated High Speed CAN
Transceiv er
Recommend twisted pair (one twist per 2")
with terminating resistor. Contact AEM f or
additional inf ormation.
C1-32
CANH_Aout
AEMNet CANH
Dedicated High Speed CAN
Transceiv er
Recommend twisted pair (one twist per 2")
with terminating resistor. Contact AEM f or
additional inf ormation.
C1-33
LowsideSwitch_1
Boost Control
Lowside switch, 4A max with
internal f ly back diode. Inductiv e
load should NOT hav e f ull time
power.
See Setup Wizard page Boost Control f or
options. Monitor BoostControl [%] channel
f or output state.
C1-34
Lowside Fuel Pump driv e
Fuel Pump
Lowside switch, 4A max, NO
internal f ly back diode.
Switched ground. Will prime f or 2 seconds
at key on and activ ate if RPM > 0.