AEM 30-3500 Infinity Plug & Play Harnesses - Toyota 1993-1997 Supra Turbo User Manual

Page 18

Advertising
background image

18

© 2014 AEM Performance Electronics

P/N 30-3500

Infinity

Pin

Hardware Reference

7100-XXXX-62
7101-XXXX-63

Function

Hardware Specification

Notes

C1-35

Analog_In_7

Throttle Position

Sensor

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. See the
Setup Wizard Set Throttle Range page f or
automatic min/max calibration. Monitor the
Throttle [%] channel. Also DB1_TPSA [%]
f or DBW applications.

C1-36

Analog_In_8

MAP Sensor

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. See the
Setup Wizard Set Manif old Pressure page
f or setup and calibration. Monitor the MAP
[kPa] channel.

C1-37

Analog_In_9

Fuel Pressure

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. See the
Setup Wizard Fuel Pressure page f or setup
and calibration. Monitor the FuelPressure
[psig] channel.

C1-38

Analog_In_10

Baro Sensor

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. See the
Setup Wizard Barometric Pressure page
f or setup and calibration. Monitor the
BaroPress [kPa] channel.

C1-39

Analog_In_11

Shif t Switch Input

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU.
See the 1D lookup table 'Shif tSwitch' f or
setup. Also assignable to multiple
f unctions. See Setup Wizard f or details.

C1-40

Analog_In_12

Mode Switch

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU.
See the 1D lookup table 'ModeSwitch' f or
input state.
A multi-position rotary switch such as AEM
P/N 30-2056 is recommended.
Also assignable to multiple f unctions. See
Setup Wizard f or details.

Advertising