AEM 30-3508 Infinity Plug & Play Harnesses - Honda 2000-2005 S2000 User Manual

Page 12

Advertising
background image

12

© 2014 AEM Performance Electronics

P/N 30-3508

Infinity

Pin

Infinity

Assignment

Honda Pin

Honda Description

Infinity Hardware

Specification

Notes

52

Ana8 - Map

C17

MAP Sensor

12 bit A/D, 100K pullup to

5V

0–5V analog signal. See the Manif old
Pressure in Setup Wizard f or setup and
calibration.

53

Ana9 - Fuel

Press

---

---

12 bit A/D, 100K pullup to

5V

0–5V analog signal f ound on the Auxiliary
Connector

54

VR2 (+) -

Driv en

Wheel

---

---

Dif f erential Variable

Reluctance Zero Cross

Detection

See Driv en Wheel Speed Calibration in the
Setup Wizard Vehicle Speed page.

55

VR2 (-) -

Driv en

Wheel

---

---

Dif f erential Variable

Reluctance Zero Cross

Detection

See Driv en Wheel Speed Calibration in the
Setup Wizard Vehicle Speed page.

56

VR3 (-) - Tag

Wheel

---

---

Dif f erential Variable

Reluctance Zero Cross

Detection

See Non Driv en Wheel Speed Calibration in
the Setup Wizard Vehicle Speed page.

57

VR3 (+) - Tag

Wheel

---

---

Dif f erential Variable

Reluctance Zero Cross

Detection

See Non Driv en Wheel Speed Calibration in
the Setup Wizard Vehicle Speed page.

58

HS Out 0

B12

VTEC solenoid Valv e

0.7A max, High Side Solid

State Relay

+12V High Side Driv e. See Setup Wizard
Honda VTEC page f or options.

59

Stepper_1B

---

---

Automotiv e, Programmable

Stepper Driv er, up to 28V

and ±1.4A

Be sure that each internal coil of the stepper
motor is properly paired with the 1A/1B and
2A/2B ECU outputs. Supports Bi-Polar stepper
motors only .

60

Stepper_2B

---

---

Automotiv e, Programmable

Stepper Driv er, up to 28V

and ±1.4A

Be sure that each internal coil of the stepper
motor is properly paired with the 1A/1B and
2A/2B ECU outputs. Supports Bi-Polar stepper
motors only .

61

HBridge0_0

---

---

5.0A max Throttle Control

Hbridge Driv e

2000–2005 S2000 do not use driv e by wire
throttle.

62

HBridge0_1

---

---

5.0A max Throttle Control

Hbridge Driv e

2000–2005 S2000 do not use driv e by wire
throttle.

63

+12V

---

---

Main Power

12 v olt power f rom relay powers the Inf inity ,
Lambda sensor, and AEMNet

64

Injector 6 -

Peak & Hold

---

---

Saturated or peak and hold,

3A max continuous

Spare injector output

65

Injector 5 -

Peak & Hold

---

---

Saturated or peak and hold,

3A max continuous

Spare injector output

66

Injector 4 -

Peak & Hold

B5

Injector 4

Saturated or peak and hold,

3A max continuous

Injector 4

67

GND

B22

Logic Ground 2

Power Ground

Connects directly to ground

68

+12V

---

---

Main Power

12 v olt power f rom relay powers the Inf inity

69

Ana19 -

APP2

---

---

12 bit A/D, 100K pullup to

5V

0–5V analog signal. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU.

70

Ana18 -

APP1

---

---

12 bit A/D, 100K pullup to

5V

0–5V analog signal. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU.

71

Ana16

- Throttle2

---

---

12 bit A/D, 100K pullup to

5V

0–5V analog signal f ound on the Auxiliary
Connector

Advertising