C1-19

AGND_1

Dedicated analog ground

Analog 0-5V sensor ground

C1-20

AGND_1

Dedicated analog ground

Analog 0-5V sensor ground

C1-21

Crankshaft
Position Sensor
Hall

10K pullup to 12V. Will work with ground or
floating switches.

See Setup Wizard page Cam/Crank for options.

C1-22

Camshaft Position
Sensor 1 Hall

10K pullup to 12V. Will work with ground or
floating switches.

See Setup Wizard page Cam/Crank for options.

C1-23

Digital_In_2

10K pullup to 12V. Will work with ground or
floating switches.

See Setup Wizard page Cam/Crank for options.

C1-24

Digital_In_3

10K pullup to 12V. Will work with ground or
floating switches.

See Setup Wizard page Turbo Speed for calibration constant.
TurboSpeed [RPM] = Turbo [Hz] * Turbo Speed Calibration.

C1-25

Digital_In_4

10K pullup to 12V. Will work with ground or
floating switches.

See Setup Wizard page Vehicle Speed for calibration constant.

C1-26

Digital_In_5

10K pullup to 12V. Will work with ground or
floating switches.

See channel FlexDigitalIn [Hz] for raw frequency input data.

C1-27

Knock Sensor 1

Dedicated knock signal processor

See Setup Wizard page Knock Setup for options.

C1-28

Knock Sensor 2

Dedicated knock signal processor

See Setup Wizard page Knock Setup for options.

C1-29

+12V_Relay_Cont
rol

0.7A max ground sink for external relay control

Will activate at key on and at key off according to the
configuration settings.

C1-30

Power Ground

Power Ground

Connect directly to battery ground

C1-31

CANL_Aout

Dedicated High Speed CAN Transceiver

Recommend twisted pair (one twist per 2") with terminating
resistor. Contact AEM for additional information.

C1-32

CANH_Aout

Dedicated High Speed CAN Transceiver

Recommend twisted pair (one twist per 2") with terminating
resistor. Contact AEM for additional information.

C1-33

LowsideSwitch_1

Lowside switch, 4A max with internal flyback diode.
Inductive load should NOT have full time power.

See Setup Wizard page Boost Control for options. Monitor
BoostControl [%] channel for output state.

C1-34

Lowside Fuel
Pump drive

Lowside switch, 4A max, NO internal flyback diode.

Switched ground. Will prime for 2 seconds at key on and
activate if RPM > 0.

C1-35

Analog_In_7

12 bit A/D, 100K pullup to 5V

0-5V analog signal. Use +5V Out pins as power supply and
Sensor Ground pins as the low reference. Do not connect
signals referenced to +12V as this can permanently damage
the ECU. See the Setup Wizard Set Throttle Range page for
automatic min/max calibration. Monitor the Throttle [%]
channel. Also DB1_TPSA [%] for DBW applications.

C1-36

Analog_In_8

12 bit A/D, 100K pullup to 5V

0-5V analog signal. Use +5V Out pins as power supply and
Sensor Ground pins as the low reference. Do not connect
signals referenced to +12V as this can permanently damage
the ECU. See the Setup Wizard Set Manifold Pressure page for
setup and calibration. Monitor the MAP [kPa] channel.

C1-37

Analog_In_9

12 bit A/D, 100K pullup to 5V

0-5V analog signal. Use +5V Out pins as power supply and
Sensor Ground pins as the low reference. Do not connect
signals referenced to +12V as this can permanently damage
the ECU. See the Setup Wizard Fuel Pressure page for setup
and calibration. Monitor the FuelPressure [psig] channel.