Analog output – AEM 30-5130 Analog Wideband UEGO Gauge Gasoline AFR User Manual

Page 5

Advertising
background image



# of Flashes

Fault

Corrective Action

1-6

Sensor Wiring and/or sensor

Check sensor cable for

broken wires/shorts

7

System voltage below 10 volts dc

Check electrical system

for good connections

and proper function

Table 1. Error Codes


Analog Output

The analog output from the AEM Analog Wideband Air/Fuel Ratio gauge is a linear dc
voltage signal that varies from 0.5 Vdc at 8.5:1 AFR to 4.5Vdc at 18.0:1 AFR over the
operating range of the gauge. The signal is used for sending information to a data
logger or an engine management system like the AEM EMS or F/IC. The transfer
function for the output is listed below.

AFR = 2.375(V) + 7.3125

For example, if the output is 2.0 Vdc, the AFR is 12.06:1
2.375 * 2.0 + 7.3125 = 12.06

Configuring the AEM EMS

With an EMS calibration open, go to Setup>Sensors>Oxygen Sensor #1(2)>O2 Sensor
#1(2) Cal Table>Table, and enter the values below into the O2 Sensor #1(2) Cal Table.


Voltage AFR

Voltage AFR

Voltage AFR

Voltage AFR

0.00 8.43 1.40 10.64

2.81

13.99

4.21 17.31

0.16 8.43 1.56 11.02

2.96

14.34

4.37 17.69

0.31 8.43 1.72 11.40

3.12

14.72

4.52 18.05

0.47 8.43 1.87 11.75

3.28

15.10

4.68 18.05

0.62 8.79 2.03 12.13

3.43

15.46

4.84 18.05

0.78 9.17 2.18 12.49

3.59

15.84

4.99 18.05

0.94 9.55 2.34

12.87

3.74

16.20

NA

NA

1.09 9.90 2.50

13.25

3.90

16.58

NA

NA

1.25 10.28 2.65 13.61

4.06

16.96

NA

NA


Table 2. EMS Software Values




Connect the WHITE Analog Output + wire to the EMS Lambda input and the BROWN
Analog Output – wire to the EMS sensor ground. Table 3 below lists the Lambda and
Sensor ground pin locations for the different EMS part numbers.


Page 5