Connection Diagram for EMS P/N 30-6100

1993-1998 Toyota Supra

WARNING: pin labeling scheme follows Toyota service manual convention; diagram shows wire side of

connector. Pin labels molded into plastic connector may not be accurate, check diagram carefully.

Pin#

93-98 Supra 2JZGTE

AEM P/N 30-6100

I/O

Availability & Notes

1A

Switched 12v at key on

Main Relay circuit

Input

Dedicated, activates Switch 1 input

2A

Vehicle Speed Sensor

Car Speed

Input

PnP for VSS signal (MT)*

3A

Kickdown switch

Switch 3

Input

Available, switch must connect to GND

4A

Brake switch input (12V)

Switch 6

Input

Available, switch must connect to GND

5A

---

---

---

Not Used

6A

Malfunction Indicator Lamp

LS10

Output

Available, switched GND output (1.5A max)

7A

Reverse indicator input, A/T only

ATPR (GEAR)

Input

PNP reverse input (auto only)

8A

SDL (98 only)

---

---

Not Used

9A

2nd gear indicator input, A/T only

ATP2 (GEAR)

Input

PNP 2nd gear indicator (auto only)

10A

1st gear indicator input, A/T only

ATP1 (GEAR)

Input

PNP 1st gear indicator (auto only)

11A

ABS to ABS and TRAC ECU

CAN1L

Output

Dedicated

12A

OD1 to cruise control ECU

CAN1H

Output

Dedicated

13A

TRC - To TRAC ECU

Reserved

---

Reserved for future use

14A

TRC+ To TRAC ECU

Reserved

---

Reserved for future use

15A

ELS for Idle up Diode

---

---

Not Used

16A

LS7 (Tach out for climate control)

LS7

Output

PnP for Tacho Out

17A

TT For DATALINK connector

Injector 12

Output

Available, P&H Injector driver 4A/1A

18A

Trans mode selector sw (A/T only)

Switch 5

Input

PnP for Manual trans mode (auto only)

19A

TE2 to DATALINK connector

Injector 11

Output

Available, P&H Injector driver 4A/1A

20A

TE1 For DATALINK connector

---

---

Not Used

21A

DI from Fuel Pump ecu

---

---

Not Used

22A

Fuel pump control (FPC)

Coil 8 / LS8

Output

PnP 0- 5V FPC signal, not for use with relays

23A

ACMG to A/C Magnetic clutch

LS6

Output

PNP for A/C compressor relay

24A

Main Relay Control

Main Relay (HS2)

Output

Dedicated, activates Main Relay with 12V

25A

Trans mode light (A/T only)

ATIND (Coil7)

Output

PNP manual mode indicator (auto only)

26A

EFI - to TRAC ECU

EFI-TRC

Input

Dedicated

27A

EFI+ to TRAC ECU

EFI+TRC

Input

Dedicated

28A

Over Drive Switch input (A/T only)

Switch 4

Input

PNP for Overdrive input (auto only)

29A

---

Baro (ADCR12)

Input

Available, Spare 0-5V Sensor Input

30A

---

---

---

Not Used

31A

+12V Power from main relay

+12V Switched

Both

Dedicated

32A

---

---

---

Not Used

33A

+12V permanent battery backup power

Permanent +12V

Input

Dedicated, used to store internal datalog

34A

A/C signal from A/C amplifier

ADCR11

Input

PNP for Air Conditioning request switch

35A

---

HALLPWR

Output

+12V Output

36A

---

Injector 8

Output

Spare P&H Injector 4A/1A

37A

---

---

---

Not Used

38A

NEO to TRAC ECU

LS7

---

PnP for spare Tacho Out

39A

VTO2 (98 only)

---

---

Not Used

40A

VTO1 (98 only)

---

---

Not Used