AEM Infinity Supported Applications - Dodge HEMI Engine User Manual

Page 6

Advertising
background image

6

© 2014 AEM Performance Electronics

Infinity

Pin

Hardware Reference

7100-XXXX-62
7101-XXXX-63

Function

Hardware Specification

Notes

C1-10

+12V_R8C_CPU

Battery Perm Power

Dedicated power management
CPU

Full time battery power. MUST be
powered bef ore the ignition switch input
is triggered. (See C1-65.)

C1-11

Coil 4

Coil 4

25 mA max source current

0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.

C1-12

Coil 3

Coil 3

25 mA max source current

0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.

C1-13

Coil 2

Coil 2

25 mA max source current

0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.

C1-14

Coil 1

Coil 1

25 mA max source current

0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.

C1-15

Coil 6

Coil 6

25 mA max source current

0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.

C1-16

Coil 5

Coil 5

25 mA max source current

0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.

C1-17

LowsideSwitch_2

Coolant Fan 1 Control

Lowside switch, 4A max, NO
internal f ly back diode.

See "LowSide Assignment Tables" f or
output assignment.

C1-18

LowsideSwitch_3

MIL Output

Lowside switch, 4A max with
internal f ly back diode. Inductiv e
load should NOT hav e f ull time
power.

See Wizard page "LowSide Assignment
Tables" f or output assignment.
MIL Activ ates when any of the f ollowing
f lags are true: ErrorAirTemp, ErrorBaro,
ErrorCoolantTemp, ErrorEBP,
ErrorFuelPressure, UEGO_0_Diag_error,
UEGO_1_Diag_error, ErrorMAFAnalog,
ErrorMAFDigital, ErrorMAP,
ErrorOilPressure, ErrorThrottle.

C1-19

AGND_1

Sensor Ground

Dedicated analog ground

Analog 0–5V sensor ground

C1-20

AGND_1

Sensor Ground

Dedicated analog ground

Analog 0–5V sensor ground

C1-21

Crankshaf t Position
Sensor Hall

Crankshaf t Position

Sensor Hall

10K pullup to 12V. Will work with
ground or f loating switches.

See Setup Wizard page Cam/Crank f or
options.

C1-22

Camshaf t Position
Sensor 1 Hall

Camshaf t Position

Sensor 1 Hall

10K pullup to 12V. Will work with
ground or f loating switches.

See Setup Wizard page Cam/Crank f or
options.

Advertising