AEM Infinity v96 Infinity EMS Version 2.96 Upgrade Notes User Manual

Page 3

Advertising
background image

3

© 2014 AEM Performance Electronics

Option added to hide 3D graph background grid.
The USB get logs window is now displayed prior to retrieving the list of files from the
usb drive. An hour glass (or spinning circle depending on OS) is also displayed while
the getting the list.
Can now right click on either axis to bring up a menu to change colors or number
formatting. (for 1d and 2d tables)
Users can now add a Session ID string to their files. This is stored on the ECU and
can be a unique identifier for the calibration that is separate from the filename.
Users can now add control windows to the layout file by right clicking on the
background window.
A new color (modified) added to the theme. The values for the tables and graphs now
display those values that have not been committed. For tables, the modification is
displayed as the color in the border of the cell. The axis are also displayed as
modified for tables.
The legend in the 3dgraph is now placed in the top right corner.Only the 'cell' data is
used for the legend rather than the computed real/interpolated values.
Option added to automatically enable "Goto Live Data" [Ctrl G] when Logging>start
PC logging [Ctrl l] is requested.

Setup Wizard Changes:

Simplified layout of drive by wire setup page.
Added 1D table LamdaFB_I to Lambda Control setup page.
New setup page features added to support lambda feedback functionality on
Lambda3 analog input.
New look and feel for input/output setup. Tabs added to make interface more intuitive.
Simplified layout of vehicle speed input setup page.
Features added to allow more flexible MIL output setup.
Features added to make mode switch input setup more intuitive.
Features added to make turbo speed calibration and setup easier.

Known Bugs:

For 7111 Inf-812 models, selecting the Secondary Injector flow & offset data from the
wizard will set flow and offset correctly but will not populate the FI_DutyCycSec,
FI_OpenSec tables as expected. The primary injector tables FI_DutyCyc and
FI_OpenTimeX will be populated with the correct values, and it is necessary to copy/
paste these in to the FI_DutyCycSec, FI_OpenSec tables.
The Output Setup Wizard selection 'General Purpose' cannot be selected if the current
setting is 'Blank'. The workaround is to select any other function first and then select
'General Purpose', or enter any non-zero data into that specific Lowside Duty table in
the main layout.
After changing any table x- or y-axis input, the 'live cursor' for that table will not be
displayed correctly. Solution is to re-load the layout.