SELECTING A LOCATION FOR THE KEYPAD

1

Make sure that AC Power is available nearby.

TIP:

Be careful of studs, electrical wires and pipes in the wall.

2

Use the keypad’s back cover as a template to mark the screw holes 
with a pencil and the power (wiring) access hole.

3

Use a drywall saw to cut the wiring hole.

Mounting the Keypad

1

Use the 3 screws and anchors that are supplied to attach the 
mounting plate to the wall.

2

Route 18 AWG wire between the keypad and the location of the 
power supply.

Wire Size and Length

To ensure proper operation, Do Not exceed the following maximum 
length for the wire size installed:

To ensure that the appropriate wire size and length are installed, 
measure the voltage between the power connection terminals at the 
back of the control panel. The voltage measured must not fall below 11 
volts DC or nuisance “AC Power Loss” messages may be displayed and 
reported.

NOTE:

In the United States, wiring routed inside walls, ceilings, and 

floors must comply with requirements of the National Electrical 
Code, ANSI/NFPA 70 and local building codes. For wiring from 
the output of the 2GIG class II power supply, wiring rated CL2, 
CL2X, CL2R, or PLTC is recommended to satisfy these 
requirements. If this wiring is installed in an air plenum (space 
used for environmental air exchange) it must be rated CL2P 
(plenum rated).

Connect the Power Wires to the Keypad

1

Re‐connect the hanging strap.

2

Use #6 insulated spade terminals (not supplied) to connect wires 
from the power supply to the keypad.

3

Close the keypad.

4

Connect the power wires to the power supply.

Wire Size

Maximum Length

22 AWG

55 feet (16.8 meters)

20 AWG

85 feet (25.9 meters

22 AWG 2‐pairs
(19 AWG equivalent)

110 feet (33.5 meters)

18 AWG

135 feet (41.1 meters)

A Snap case closed.
B Tighten case screw.

A Left Terminal 14 VDC(+)
B Right Terminal 14 VDC (-)
C 18 AWG/2-Conductor