12

FLA

VOR

INP

UT

1

2

WA

TER

INP

UT

REF

ILL

MA

IN

PO

WE

R

2

1

1

2

3

3

3

FLA

VO

R

OU

TPU

T

FLA

VO

R

OU

TPU

T

WA

TER

OU

TPU

T

FLA

VO

R

OU

TPU

T

WA

TER

OU

TPU

T

WA

TER

OU

TPU

T

P1522

FIG. 7 MAIN ON/OFF SWITCH TERMINALS

BLK from Fuse Holder

BLK to Solenoid (Water)

Switch #2 AFPO-2 & 3

MAIN ON/OFF SWITCH

FIG. 6 MAIN ON/OFF SWITCH

P1516

Location:

The main ON/OFF switch is located on the lower

right front of the autofill box just above the power

cord.

Test Procedure:

1. Disconnect the dispenser from the power

source.

2. Disconnect the black wire from the fuse holder

and the white wire from pump #1.

3. Connect the dispenser to the power source. Check

for voltage across the black wire removed from

the switch and the white wire removed from pump

#1. The indication must be:

a) 120 volts ac for 2 wire 120 volt models.

b) 200 to 240 volts ac for two wire 200 or 240 volt

models.

c) 230 volts ac for two wire 230 volt models.

4. Disconnect the dispenser from the power

source.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the Wiring

Diagrams and check the dispenser wiring harness.

SERVICE (cont.)

5. Check for continuity across the switch terminals

with the switch in the “ON” position. Continuity

must not be present when the switch is in the

“OFF” position.

If continuity is present as described, reconnect the

wires to the switch terminals.

If continuity is not present as described, replace the

switch.

Removal and Replacement:

1. Remove the wires from the switch terminals.

2. Compress the clips inside the autofill box and

gently push the switch through the opening

3. Push the new switch into the opening and spread

the clips to hold switch in the autofill box.

4. Refer to Fig. 7 when reconnecting the wires.

41093 040408