Functions and performance 4 – Lukas CT7 User Manual

Page 9

Advertising
background image

9

Functions and performance

4.

4.1 Description

The control desks in the CT7 model series comprise a number of valves housed in a control

block. The valves are controlled by means of control levers.

Depending on the version, up to 6 double-acting and 2 single-acting hydraulic devices can

be connected and controlled without the need for a separate controller.

The attached, manually operated pressure shut-off valve opens and closes the supply to the

control valves. With the manual pressure shut-off valve in the “closed” position, the flow to

WARNING / DANGER / CAUTION!

The manual pressure shut-off valve closes

only the connection to the hydraulic

unit to be supplied.

It is NOT provided as an “emergency stop” function. This means that the

connected hydraulic devices could still move if one of the control levers were

operated. This could happen if residual pressure in the system or external loads

were to act on the connected hydraulic devices.

the hydraulic pump is automatically depressurised.

The control desks are usually mounted on a separate pedestal or secured directly to the unit

frame. LUKAS control desks are normally always delivered mounted on a pedestal or fitted

to a frame. To find out more, please contact your authorised LUKAS dealer.

The control desk also features a pressure gauge on the inlet block as standard. This pressure

gauge indicates the pressure acting on the control desk from the unit.

Only LUKAS motor pumps are permitted to be used to drive the devices.

If an other-make pump power pack is used, it is important to ensure that it complies with

LUKAS specifications, as otherwise dangerous situations beyond the control of LUKAS

could arise. Particular care must be taken to ensure that the maximum permissible operating

pressure of the connected LUKAS devices is not exceeded.

REMARK:

Before you use pumps of a different manufacturer, you must contact LUKAS or

an authorised dealer.

The connection to the supplied hydraulic pump and to the implements is established by

means of hose lines, which are connected to each other by couplings.

4.2 Hydraulic supply

CAUTION!

Due to ram pressures in the hose lines, the maximum overall length of the hose

lines, from the unit to the control desk to the hydraulic device, is limited to 40 m

(131.2 ft.).

Long hose lines between the implement and control desk or unit and control desk

may result in delayed movement of the hydraulic implements (particularly in the

event of the automatic return of single-acting implements).

For work involving long hose lines at low ambient temperature, we recommend

the use of a hydraulic fluid with a low viscosity.