GROUNDING (EARTHING)
INSTRUCTIONS

This appliance must be grounded (earthed) and
is equipped with a cord having an equipment-
grounding (earthing) conductor and grounding
(earthing) plug. The plug must be plugged into an
appropriate outlet that is properly installed and
grounded (earthed) in accordance with all local
codes and ordinances.

DANGER

Improper connection of an equipment-grounding
(earthing) conductor can result in risk of electric-
shock. Do not modify the plug provided with the
appliance. If it will no

the outlet, have proper

outlet installed by a quali ed technician. This
appliance is for use in a regular electrical circuit,
corresponding to the electrical standard in your
country.

PLANNING

If your home already has a system of plastic
tubing and inlet valves, you are ready to install
the power unit (refer to Power Unit Installation
section). If not, you may have the system installed
by a professional or you may choose to do it
yourself. If you install the system yourself, it is
important to carefully plan the location of each
inlet valve, the power unit, and the network of
plastic tubing. This booklet deals only with the
installation of the power unit; “How-To” booklets
generally are included with installation kits.

4

Power Unit Location

The power unit is connected to inlet valves via a
system of lightweight plastic tubing installed in the
walls of your home.

The power unit should be located as far from the
general living area as possible, yet accessible
so you can remove the dirt receptacle, reach
the lter, and inspect the unit. Typical locations
are utility room, basement or garage. It is
recommended that the exhaust be vented outside;
never into a wall, a ceiling, or a concealed space
in the house.

Power Unit Wiring

The power unit must be mounted within 1.8m of a

Power Unit Installation

The power unit hangs on a mounting bracket
which is screwed to the wall. The bottom screws
of the mounting bracket should be about 1.2m up
from the oor for convenient removal of the dust
receptacle (or at least 70cm from the oor). For
proper motor cooling, mount the power unit at
least 30cm from the ceiling and any adjacent wall.

grounded (earthed) electrical outlet. Be sure your

house agrees with the voltage on the Rating Plate

and do not overload the circuit.