JUN-AIR Dental Compressed Air System User Guide

CI-101A (Rev B)

MAINTENANCE

Also to extend your compressor life, please do the

following:
• Keep compressor system clean and free of dirt

and debris .

• Keep area surrounding compressor system

clean and free of debris .

• Maintain recommended controlled ambient

temperature – high temperatures will shorten life .

• Verify all leaks are sealed.

Replace Intake Filter Element
1 . Turn off compressor system .
2 . Disconnect compressor system from electrical

power .

3 . Remove intake filter cap by pressing it down and

rotating while holding base of filter .

4 . Remove old intake filter element and discard .
5 . Install replacement filter element and replace filter

cap .

6 . Reconnect electrical power to system .
NOTE: To comply with NFPA99C, filter kits are

available for the JUN-AIR Compressor
System (see OPTIONS AND ACCESSORIES) .

Replacing the Coalescing Filter Element:
1 . Turn off compressor system .
2 . Disconnect compressor system from electrical

power .

3 . Bleed air from system .
4 . Push up and rotate coalescing filter bowl slightly

and remove .

5 . Remove filter element by turning completely out

and discard .

6 . Install a new 0 .01 micron filter element (verify

correct part is installed) .

7 . Position filter bowl by pushing up slightly and

rotating into place .

8 . Reconnect electrical power to system .

By performing regularly scheduled maintenance, you will ensure your compressor system provides you with
years of superior performance .

Preventive maintenance schedule in a clean, dry environment

Annually

Verify compressor fan operation

Initial installation and annually

Test for air leaks

Annually

Replace intake filter elements

Annually or when filter indicator turns red

Replace coalescing filter element

Annually or when filter indicator turns red

Replace particulate filter element

Annually

Inspect dryer, all hoses, and system functionality

Annually

Replace dryer silencers

Annually

Test safety relief valve

Every five years

Replace dessicant towers

WARNING: Always disconnect power before

servicing. The head(s) suface(s) can be very

hot depending on compressor usage. Do not

touch these parts during or directly after

operation.

Injury Hazard

Product surfaces become very hot during operation,

allow product surfaces to cool before handling.
Air stream from product may contain solid or liquid

material that can result in eye or skin damage,

wear proper eye protection.
Clean this product in a well ventilated area.
Failure to follow these instructions can result in

burns, eye injury or other serious injury.

W

A

RNING

Disconnect electrical power supply cord before

performing maintenance on this product.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before performing maintenance on this product.
Failure to follow these instructions can result in

death, fire or electrical shock.