Eagledrive lead wire assignments – Micropump EagleDrive ELE User Manual

Page 13

Advertising
background image

13

DOC No: 8540 REV D

MODEL MS

1

2

3

4

5
7

8

9

6

1

2

3

4

5
7

8

9

6

MODEL EL

Lead

Function

Color

1

Power In

Red

+12 to +36 VDC, Class 2 (SELV),

Reverse-polarity protected

2

Common

Black

Isolated from motor housing

3

Control Signal In

Yellow

0-5 VDC

4

Tachometer Out

Green

5 V square wave-2 pulses per

revolution

5

FWD/REV

Orange

Forward (float and insulate), Reverse

(ground)

qww

Not Connected

Violet

None

7

Error Out

Blue

Fault Signal 2

8

Error Out

Brown

Fault Signal 1

9

Shield

-

Connected to Common