MOS90 Fault Finding Flow Charts

Section 3 - Troubleshooting

Page 3-12

067448-003 LX31/LX41 Electric Work Platform

8 Flashes

- Ther mal cutback

- Heatsink temperature less

than 80ºC (176ºF) (Current
limit will be zero at 90ºC
(194ºF)

- Allow unit to cool down, to

clear flashing

Check current limit setting

Re-set

Check mounting and heatsink of controller

Rectify

Check application is correct

Use larger controller

Replace MOS90 Controller

10 Flashes

- Tachometer fault

- Drive inhibited

- Recycle key to clear fault

Check tachometer wires for opens or shorts

Rectify

Check output voltage from tachometer using

voltmeter

Replace

Check output voltage from tachometer board,

using voltmeter

Replace

Replace MOS90 Controller

Advertising