MOS90 Fault Finding Flow Charts

Section 3 - Troubleshooting

Page 3-14

067448-003 LX31/LX41 Electric Work Platform

LED off

- Unit not powered up or controller

faulty, or LED faulty

Check battery is connected and keyswitch is on

Rectify

Check all fuses are intact

Rectify

Check supply wiring. Does calibrator unit still

function

Rectify

Controller is faulty:

a) Auto fail-safe check failed. LED turns off when

a direction is first selected after power up.
Recycle keyswitch.

b) Contactor drive S/C. LED resets itself if short

circuit clears.

c) Mosfets did not turn on. Recycle direction to

neutral to clear fault indication.

Replace controller

14 Flashes

- Battery voltage has fallen out

of range.

- Traction and pump mode will

not be allowed

- Requires key recycle to clear

fualt

Check battery voltage (under load) with a voltme-

ter or calibrator

Change/charge battery

Check power connections, fuses, etc.

Repair/replace

Check for battery leakage to frame

Rectify

Replace MOS90 Controller