background image

Chapter 6 – Controls

24

AB60J – 0181972

if the cause of the malfunction is not corrected. Do

not operate the aerial platform if the circuit breaker

trips repeatedly.

Push the button to reset the circuit breaker.

Upper Controls

The upper controls (refer to Figure 6.4) are located on the

control panel at the platform. Boom, platform, and drive

functions can be operated from the upper controls.

The following controls are located on the upper control

panel:

Emergency stop button

Start switch

Boom joystick

Riser boom elevation switch

Boom extension switch

Jib boom elevation switch

Boom speed knob

Drive joystick

Drive range switch

Platform level switch

Platform rotation switch

Engine/emergency power switch

Throttle switch

Horn (option)

Hydraulic system warm-up switch (option)

Start Switch

The engine can be started from the platform using the

start switch on the front of the upper control panel (refer

to Figure 6.4). This switch is similar to an automobile

ignition switch.

Turn the switch to start until the engine starts, then

release it to on.

If the engine dies, the switch must be turned to off

before it can be turned back to start.

An alarm sounds, when the switch is turned on, to warn

others that the machine engine is being started.

Note

On some machines it may be necessary to pause about

three seconds in the on position before going to start so

the starter can engage.

If the platform is to stay in a particular position for a long

time, turn the start switch to off to shut off the engine and

save fuel.

Emergency Stop Button

The emergency stop is a two-position, red push button on

the top of the upper control panel (refer to Figure 6.4).

Push the button inward to disconnect power from all

control circuits at the upper controls.

Pull the button outward to restore power.















To warm-up the hydraulic fluid from the lower controls:

1. Start the engine from the lower controls.

2. Place the hydraulic fluid warm-up switch in the on

position.

The engine throttle speed will increase to warm

the hydraulic fluid.

The engine throttle speed will decrease and

return to idle once the hydraulic fluid reaches a

preset temperature.

If the warm-up switch is left on the engine speed

will continue to increase and decrease to keep

the hydraulic fluid at a preset temperature.

3. When the engine throttle speed returns to idle, place

the hydraulic fluid warm-up switch in the off posi-

tion.

Circuit Breaker Reset Buttons

The lower control panel has a circuit breaker for the

throttle, run, and system control circuits. There is a reset

button for each circuit breaker on the front of the lower

control panel (refer to Figure 6.2).

The upper control panel has a circuit breaker for the swing

(turntable rotation), lift, drive and main control circuits.

The circuit breakers are on the front of the upper control

panel (refer to Figure 6.3).

Figure 6.3 – Platform

The electrical power outlet at the platform has a 15 amp

circuit breaker. The reset button is on the right side of the

electrical box (refer to Figure 6.3).

The circuit breakers protect the electrical wiring and

components from electrical overload in case of a short

circuit or other fault.

Caution

A tripped circuit breaker indicates a malfunction in

the electrical system. Component damage can result

Upper Control

Circuit Breaker Reset Buttons

Electrical Outlet

Circuit Breaker

Reset Button

Advertising