Hydraulic system warm-up switch, Manually warming the hydraulic system, Preparing for operation – Snorkel AB60J User Manual

Page 50: Lower controls, Caution

Advertising
background image

Chapter 8 – Operation

46

AB60J – 0181972

4. Before painting or sandblasting make sure the sand-

blast protection kit and the platform control cover are

properly installed. These options, when used properly

will protect the control placards and cylinder rods from

paint overspray and abrasion while sandblasting.

Lower Controls

The lower controls override the upper controls. This

means that the lower controls can always be used to

operate the platform regardless of the position of the

upper control emergency stop button.

Boom, turntable, and platform functions may be operated

from the lower controls. The lower controls may be used

for initial set up of the aerial platform, and for testing and

inspection.

Use the following procedure to operate boom, turntable,

or platform functions using the lower controls.

1. On dual fuel machines, set the fuel switch to either

LPG or gasoline (refer to Figure 8.2).

Figure 8.2 – Lower Controls

2. Open the shut-off valve on the tank if using LPG.

3. Pull the emergency stop button (refer to Figure 8.2)

outward and place the control selector switch in the

lower control position.

4. Turn the start switch to on and pause a few seconds

while the alarm sounds to alert others that the ma-

chine is about to start. Turn the switch to start, then

release it to on. The engine will not start if the switch is

left in the on position for 30 seconds or longer before

turning it to start. The switch must be turned back to

off before the engine will start.

Note

If the machine has a GM engine, there will be a 7 to 10

second delay after starting the engine, before the throttle

will go to mid or high. Start the engine and wait 10 seconds

before proceeding with machine operation.

5. Let the engine warm to operating temperature.

teristics and can increase component wear. Only use

hydraulic fluid as recommended.

Use cold weather hydraulic oil as recommended in the

machine General Specifications in temperatures of 10°F

(-12°C) or below.

Hydraulic System Warm-up Switch

This system may be used to warm the hydraulic fluid when

the ambient temperature is below 32°F (0°C) and boom

movement is sluggish because of cold fluid.

There may be a toggle switch for the warm-up system on

the lower control panel and/or one on the upper control

panel.

The engine must be running and the switch used to turn

the system on must be at the same location that the en-

gine was started. For example, if the engine was started

from the lower controls, the warm-up switch at the lower

controls must be used for the system to operate.

To operate the warm-up system:

1. Start the engine and place the engine throttle in the

low position.

2. From the same control station that the engine was

started, place the warm-up switch in the on posi-

tion.

3. After the hydraulic fluid reaches 50°F (10°C) as indi-

cated on the thermometer, place the warm-up switch

in the off position.

Manually Warming The Hydraulic System

The hydraulic oil may be warmed by bottoming out the

boom extension cylinder. Raise the main boom so it is

horizontal and operate the boom retract function while the

machine is stowed. With the cylinder bottomed out the oil

flow will produce heat to warm the hydraulic oil.

Caution

Not all hydraulic fluid is suitable to use in the hy-

draulic system. Some have poor lubricating charac-

teristics and can increase component wear. Only use

hydraulic fluid as recommended.

Use cold weather hydraulic oil as recommended in the

machine General Specifications in temperatures of 10°F

(-12°C) or below.

Preparing for Operation

Use the following procedure to prepare the aerial platform

for operation:

1. Perform a prestart inspection as described in Chapter 7.

2. Place the battery disconnect switch in the on position.

3. Close and latch the cowling doors.

Emergency

Stop Button

Control Selector

Switch

Ground Operation

Switch

Start Switch

Fuel Switch

Advertising