Electrical system – JLG 4017PS Service Manual User Manual

Page 220

Advertising
background image

Electrical System

9-62

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

MAIN LIFT DOWN

VALVE – OPEN

CIRCUIT

33184

5000mS

Lift Down is prevented

Open-circuit is detected on UGM

J2-22

Power cycled

MAIN LIFT DOWN

VALVE – SHORT

TO GROUND

33185

Continuously

Lift Up is prevented

Lift Down is prevented

UGM J3-2 Lift Return is disabled

Short to ground is detected on

UGM J2-22

Power cycled

MAIN TELESCOPE

OUT VALVE –

OPEN CIRCUIT

33186

5000mS

Telescope Out is prevented

Open-circuit is detected on UGM

J2-35

Power cycled

MAIN TELESCOPE

VALVES – SHORT

TO BATTERY

33187

Continuously

Telescope Out is prevented

Telescope In is prevented

UGM J3-4 Telescope Return is

disabled

Short to battery is detected on

UGM J2-34 or UGM J2-35

Power cycled

MAIN TELESCOPE

OUT VALVE –

SHORT TO

GROUND

33188

Continuously

Telescope Out is prevented

Telescope In is prevented

UGM J3-4 Telescope Return is

disabled

Short to ground is detected on

UGM J2-35

Power cycled

MAIN TELESCOPE

IN VALVE – OPEN

CIRCUIT

33189

5000mS

Telescope In is prevented

Open-circuit is detected on UGM

J2-34

Power cycled

MAIN TELESCOPE

IN VALVE –

SHORT TO

GROUND

33190

Continuously

Telescope Out is prevented

Telescope In is prevented

UGM J3-4 Telescope Return is

disabled

Short to ground is detected on

UGM J2-34

Power cycled

FORK TILT UP

VALVE – OPEN

CIRCUIT

33191

5000mS

Fork Tilt Up is prevented

Fork Tilt Mode is active;

Open-circuit is detected on UGM

J2-8

Power cycled

FORK TILT

VALVES – SHORT

TO BATTERY

33192

Continuously

Fork Tilt Up is prevented

Fork Tilt Down is prevented

UGM J3-6 Tilt Return is disabled

Short to battery is detected on

UGM J2-8 or J2-19

Power cycled

FORK TILT UP

VALVE – SHORT

TO GROUND

33193

Continuously

Fork Tilt Up is prevented

Fork Tilt Down is prevented

UGM J3-6 Tilt Return is disabled

Fork Tilt Mode is active;

Short to ground is detected on

UGM J2-8

Power cycled

FORK TILT DOWN

VALVE – OPEN

CIRCUIT

33194

5000mS

Fork Tilt Down is prevented

Fork Tilt Mode is active;

Open-circuit is detected on UGM

J2-19

Power cycled

FORK TILT DOWN

VALVE – SHORT

TO GROUND

33195

Continuously

Fork Tilt Up is prevented

Fork Tilt Down is prevented

UGM J3-6 Tilt Return is disabled

Fork Tilt Mode is active;

Short to ground is detected on

UGM J2-19

Power cycled

AUXILIARY

FUNCTION-A

VALVE – OPEN

CIRCUIT

33196

5000mS

Auxiliary Function-A is prevented

Continuous Auxiliary Hydraulics is

prevented

Hydraulic Quick Connect is

prevented

Auxiliary Release is prevented

Open-circuit is detected on UGM

J2-9

Power cycled