Electrical system – JLG 4017PS Service Manual User Manual

Page 233

Advertising
background image

9-75

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

k. Load Moment (85X)

LSS CELL #2 ERROR

822

Continuously

Platform assumed to be

overloaded

Machine Setup’s PLATFORM

OPTION is ENABLED; Load

Sensing System configured;

platform attached; key switch

platform;

LSS Module reports CELL 2

ERROR

Power cycled

LSS CELL #3 ERROR

823

Continuously

Platform assumed to be

overloaded

Machine Setup’s PLATFORM

OPTION is ENABLED; Load

Sensing System configured;

platform attached; key switch

platform;

LSS Module reports CELL 3

ERROR

Power cycled

LSS CELL #4 ERROR

824

Continuously

Platform assumed to be

overloaded

Machine Setup’s PLATFORM

OPTION is ENABLED; Load

Sensing System configured;

platform attached; key switch

platform;

LSS Module reports CELL 4

ERROR

Power cycled

LSS HAS NOT BEEN

CALIBRATED

825

Continuously

Platform assumed to be

overloaded

Machine Setup’s PLATFORM

OPTION is ENABLED; Load

Sensing System configured;

platform attached; key switch

platform; load sensing system has

not been calibrated

Successful

LSS

calibration

has been

performed

PLATFORM

FUNCTIONS CUTOUT

– PLATFORM

OVERLOADED

829

Continuously

Platform assumed to be

overloaded

Machine Setup’s LOAD SENSING

is PLATFORM CUTOUT; Key

switch Platform; Load Sensing

System detects an overload

(>110% or <50% rated load);

Load Sensing

System does

not detected

an overload

LOAD MOMENT

85XXX

-

-

-

-

LSI NOT

CALIBRATED

8514

5000mS

Load Monitoring configured;

LSI System reports Fault #6 –

System not calibrated

LSI System

does not

report Fault

#6

LSI DETECTED BUT

NOT CONFIGURED

8515

Continuously

Hydraulic functions are

prevented

Load Monitoring is not configured;

LSI System messages detected

Load

Monitoring is

configured

LSI LOAD CELL A –

OUT OF RANGE

8516

Continuously

Load Moment Cutout assumed to

be 100%

Load Monitoring configured;

LSI System reports Fault #4 –

Load Cell A – Out of Range

Power cycled

LSI LOAD CELL B –

OUT OF RANGE

8517

Continuously

Load Moment Cutout assumed to

be 100%

Load Monitoring configured;

LSI System reports Fault #5 –

Load Cell B – Out of Range

Power cycled