background image

SECTION 6 - JLG CONTROL SYSTEM

6-40

– JLG Lift –

3121142

HI TILTED -

NO/YES

Displays status of hi tilt input. (Displayed if external tilt sensor is configured)

AUX POWER

OP/CL

Displays the status of the auxiliary power switch input

HORN

OP/CL

Displays the status of the horn input

R FILTER

OP/CL

Displays the status of the return hydraulic filter by-pass switch. Displayed
ONLY if MODEL = 600 (Configuration digit = 3)

C FILTER

OP/CL

Displays measured status of charge pump filter bypass switch. Displayed ONLY
if MODEL = 600 (Configuration digit = 3)

JIB BLOCK

OP/CL

Displays jib block limit switch status. Not displayed if associated configuration
digit = 0

BASKET STOWD

YES/NO

Displays status of basket stowed mode. (Displayed if MODEL NUMBER = 7 or 8)

SOFT LIMIT

OP/CL

Displays status of soft touch limit switch. Not displayed if associated configu-
ration digit = 0

SOFT O/R

OP/CL

Displays status of soft touch override switch. Not displayed if associated con-
figuration digit = 0

GEN SET/WELDER

OP/CL

Displays generator/welder switch input status. Not displayed if associated
configuration digit = 0

LIGHTS

OP/CL

Displays head and tail light switch input status. Not displayed if associated
configuration digit = 0

BSK TILT1

XX.X

Displays indicated platform tilt angle. Displayed on models equipped with
Electronic Platform Leveling.

BSK TILT2

XX.X

Displays indicated platform tilt angle. Displayed on models equipped with
Electronic Platform Leveling.

AXLE RET SW

OP/CL

Displays status of axle extension user switches. (Displayed if MODEL NUMBER
= 7 or 8)

AXLE EXT SW

OP/CL

Displays status of axle retraction user switches. (Displayed if MODEL NUMBER
= 7 or 8)

AXLE LIM SW

RET/EXT

Displays status of axle extension limit switches. (Displayed if MODEL NUMBER
= 7 or 8)

DOS LIM SW

OP/CL

Displays status of Drive Orientation System Limit Switch. (Displayed if MODEL
NUMBER = 7 or 8)

DOS O/R SW

OP/CL

Displays status of Drive Orientation System Override switch. (Displayed if
MODEL NUMBER = 7 or 8)

CAPACITY SW

500/1000

Displays status of capacity selection switch. (Displayed if MODEL NUMBER = 7
or 8)

Table 6-5. Machine Diagnostics Parameters

Diagnostics Submenu

(Displayed on Analyzer

1

st

Line)

Parameter (Displayed on

Analyzer 2

nd

Line)

Parameter Value

(Displayed on Analyzer 2

nd

Line)

Description

Advertising