JLG 4394RT Service Manual User Manual

Page 164

Advertising
background image

SECTION 5 - JLG CONTROL SYSTEM

5-10

– JLG Lift–

3121133

2/6

Flash code 2/6 indicates leveling jack or power deck issues.

6

FRONT LEFT LEVELING JACK OPEN CIRCUIT

Reported by the I/O module and during system test when the
front left leveling jack is open circuit.

FRONT LEFT LEVELING JACK SHORT TO GROUND

Reported by the I/O module and during system test when the
front left leveling jack is short to ground.

FRONT LEFT LEVELING JACK SHORT TO BATTERY

Reported by the I/O module and during system test when the
front left leveling jack is short to battery.

FRONT RIGHT LEVELING JACK OPEN CIRCUIT

Reported by the I/O module and during system test when the
front right leveling jack is open circuit.

FRONT RIGHT LEVELING JACK SHORT TO GROUND

Reported by the I/O module and during system test when the
front right leveling jack is short to ground.

FRONT RIGHT LEVELING JACK SHORT TO BATTERY

Reported by the I/O module and during system test when the
front right leveling jack is short to battery.

REAR LEFT LEVELING JACK OPEN CIRCUIT

Reported by the I/O module and during system test when the
rear left leveling jack is open circuit.

REAR LEFT LEVELING JACK SHORT TO GROUND

Reported by the I/O module and during system test when the
rear left leveling jack is short to ground.

REAR LEFT LEVELING JACK SHORT TO BATTERY

Reported by the I/O module and during system test when the
rear left leveling jack is short to battery.

REAR RIGHT LEVELING JACK OPEN CIRCUIT

Reported by the I/O module and during system test when the
rear right leveling jack is open circuit.

REAR RIGHT LEVELING JACK SHORT TO GROUND

Reported by the I/O module and during system test when the
rear right leveling jack is short to ground.

REAR RIGHT LEVELING JACK SHORT TO BATTERY

Reported by the I/O module and during system test when the
rear right leveling jack is short to battery.

LEVELING JACK EXTEND VALVE OPEN CIRCUIT

Reported by the I/O module and during system test when the
leveling jack extend valve is open circuit.

Table 5-1. Fault Code Listing - Software P1.X

Fault Flash

Code

Communicated (Displayed on Analyzer) Fault

Description

Priority

Advertising