Separate backlight and electric lock supply, Connection of switch 2 – 2N Door intercom 2N Helios - Manual, 1322 v3.0 User Manual

Page 32

Advertising
background image

32

Separate Backlight and Electric Lock Supply

Separate power supplies are necessary where the lock requires voltage higher than 12
V. In this case, an additional power supply (12V) must be used to illuminate the
button backlight - see the figure below. Other reasons for such connection are the
effort to minimise consumption from the back-up supply (which supplies the lock, not
the backlight), or just that two weaker power supplies are available

Lock and Backlight Connection

Connection of Switch 2

A new additional switch, Part No. 9135250E, has been designed for 2N® Helios. It
can be mounted into any basic unit, as an added option. To connect it, follow the
instructions included in the switch delivery.


El. lock

Supply AC

or DC

max.48V

Supply AC

or DC

max.12 V

tel.

line