Technical parameters, Telephone parameters, 1 technical parameters – 2N Door intercom 2N Helios - Manual, 1322 v3.0 User Manual

Page 68: Technical parameters 5.1

Advertising
background image

Technical Parameters

5.1

68

5.1 Technical Parameters

Telephone Parameters

Parameter

Value

Conditions

Minimum required off-hook line current

15 mA

Off-hook

Minimum required on-hook line voltage

20 V

Hang-up

DC voltage drop (off-hook)

< 8 V
< 16 V

I = 25 mA

I = 50 mA

Lead current while hang-up

< 25 μA

U = 60 V

Off-hook AC impedance

220 Ω + 820 Ω
115 nF parallel

20 to 60 mA

Return loss

> 10 dB

20 to 60 mA

Bandwidth

300 to 3500 Hz

20 to 60 mA

Ringing impedance

> 2 kΩ
C = 1 μF

25 to 50 Hz

Ringing detector sensitivity

10 to 20 V

25 to 50 Hz

Time of response to ringing

Variable

Pulse dialling

40 / 60 ms

20 to 60 mA

DTMF level

-6 and -8 dB
± 2 dB

20 to 60 mA

DTMF detector sensitivity

Min. -40 dB

20 to 60 mA

Dial tone detector sensitivity

Min. -40 dB

350 - 500 Hz

Busy tone detection speed

Variable

350 - 500 Hz

Continuous tone detection speed

Variable

350 - 500 Hz

Ringing tone detection speed

Variable

350 - 500 Hz

Overvoltage protection – common mode

1000 V

8 / 20 μs

Overvoltage protection – between A, B
conductors

1000 V

8 / 20 μs

Advertising