I Operating Instructions

I - 1 Ex

ecution of S

w

itc

h

ing F

unctions

8

The CONDITION field is used to assign an axis to the output and to
specify whether the axis position is an actual-value or distance-to-go
position. You also specify the position display value at which the
relay is activated, and the required condition.

8

The POINT/RANGE field is used to define whether the conditions
refers to a point on the axis or refers to a range about zero.

8

The OUTPUT field is used to specify the relay operation when the
switching condition is met. When the condition is met, the relay is
turned OFF or ON.

Possible switching states of the relays.

If the condition is set to equal, the relay will activate
momentarily even if the switching point is crossed over too
quickly for the value to appear.